1
00:00:06,480 --> 00:00:39,079
Paul Ask What Up? What Up? Everybody? Welcome to another episode Let's

2
00:00:39,159 --> 00:00:44,000
Ask Paul, the podcast where you
get to ask me anything you want about

3
00:00:44,000 --> 00:00:49,759
the electrical industry, whether it's code, being in business, contracting theory.

4
00:00:49,840 --> 00:00:53,240
If you want go for it.
All you gotta do is go to Paul

5
00:00:53,240 --> 00:00:57,479
Abernathy dot com. It's a free
service sponsored by Wicks where you can submit

6
00:00:57,560 --> 00:01:02,320
any question you want to me and
it will be selected for an upcoming podcast

7
00:01:02,439 --> 00:01:07,000
or maybe even an email if it's
something that I feel wouldn't be very conducive

8
00:01:07,040 --> 00:01:11,640
to a podcast, I'm still going
to answer your questions. So it's a

9
00:01:11,680 --> 00:01:15,120
free service again Paul Abernathy dot com. It doesn't cost you a time.

10
00:01:15,719 --> 00:01:19,959
You also can listen to all of
the Let's Ask Paul podcast directly from that

11
00:01:19,000 --> 00:01:25,239
website as well. It's very mobile
friendly so that it adapts to mobile use.

12
00:01:25,319 --> 00:01:27,519
Just go to Paul Abernacty dot com
if you want to submit that.

13
00:01:27,799 --> 00:01:30,319
If you have our mobile app,
there's a quick feature on there that you

14
00:01:30,319 --> 00:01:34,239
can get to that right away in
the resources and that way you can do

15
00:01:34,280 --> 00:01:38,640
it in the field and we will
get you an answer. Okay, anyway,

16
00:01:38,959 --> 00:01:46,599
Welcome to today's episode. Again sponsored
by Electrical Code Academy Incorporated, is

17
00:01:46,680 --> 00:01:51,519
the leading provider of electrical code related
education. We don't do the hands on

18
00:01:51,599 --> 00:01:55,040
folks, We just do code,
whether it's residential, commercial, industrial,

19
00:01:55,079 --> 00:02:00,840
grounding and bonding, HVAC, electrical, industrial wiring, electrical got a real

20
00:02:00,920 --> 00:02:05,519
extensive course in that called Magenta.
It's not for the faint at heart,

21
00:02:05,560 --> 00:02:08,479
to tell you that. And obviously
we have our exam preps black and the

22
00:02:08,520 --> 00:02:14,520
plus and even budget courses today,
so we have a little bit for everybody,

23
00:02:14,599 --> 00:02:16,479
even if you're not preparing for an
electrical exam, but you just want

24
00:02:16,520 --> 00:02:21,360
to maybe you're a company. We
have companies who have all of their electricians

25
00:02:21,400 --> 00:02:25,599
on the program, so one they
can use it for raises and bonuses and

26
00:02:25,960 --> 00:02:30,000
if anything, is to make sure
that everybody in the company is on the

27
00:02:30,039 --> 00:02:35,719
same track now so that there's no
excitement and no surprises. Everybody's kind of

28
00:02:35,719 --> 00:02:39,520
doing the same thing. Everybody's staying
code compliant, less issues on inspections and

29
00:02:40,360 --> 00:02:45,120
yeah, you know, whatever your
choice, Electrical Code Academy has something for

30
00:02:45,159 --> 00:02:50,000
you. Just go to our website. Fast tracks system that's fast t R

31
00:02:50,080 --> 00:02:54,479
A X S, Y S T
E M dot com Okay, you could

32
00:02:54,520 --> 00:03:00,159
google fast track system online too on
any of your Google whatever being and I'm

33
00:03:00,159 --> 00:03:04,400
sure we'll come up with that too
as well. All Right, well,

34
00:03:04,599 --> 00:03:07,800
hey, thanks for joining me today
on this podcast. I've got a very

35
00:03:07,840 --> 00:03:12,560
interesting question. It was submitted and
we want to make sure that we cover

36
00:03:12,639 --> 00:03:16,520
that topic in this episode, and
also want to give a shout out to

37
00:03:16,599 --> 00:03:22,680
our fast Tracks Tube. If you
have not visited fast tracks Tube. Now,

38
00:03:22,719 --> 00:03:23,879
if you're not a subscriber, you're
not going to see a whole bunch.

39
00:03:24,080 --> 00:03:27,240
You're gonna see a bunch of stuff
that's going to require you to get

40
00:03:27,240 --> 00:03:31,639
a subscription. But what you can
see is that we have an extensive database.

41
00:03:31,719 --> 00:03:35,759
The search feature works, go to
the top type in box fille,

42
00:03:35,840 --> 00:03:38,879
for example, You're going to see
an extensive collection of videos, not by

43
00:03:38,879 --> 00:03:43,280
just me, by other educators in
the industry. And the beautiful thing about

44
00:03:43,280 --> 00:03:46,120
fast tracks Tube is that we rip
out all the commercials, none of that

45
00:03:46,199 --> 00:03:52,280
bullcrap. It's just education and all
of the videos have been vetted by me

46
00:03:52,479 --> 00:03:55,360
personally, so that you're not going
to get any fluff or poor content.

47
00:03:55,599 --> 00:04:00,800
They're all very good content, and
that's part of the reason it's a subscription

48
00:04:00,840 --> 00:04:04,080
based platform is because we spend the
time to filter out and only add stuff

49
00:04:04,080 --> 00:04:09,280
that's relevant, not the garbage that
you might get on a YouTube, and

50
00:04:09,319 --> 00:04:12,840
you usually don't know whether you can
trust the source or not. If we

51
00:04:12,879 --> 00:04:16,000
put it up on fast tracks Tube, you can trust the source. So

52
00:04:16,120 --> 00:04:19,519
basically, it's your own little video
resource in your pocket no matter where you

53
00:04:19,560 --> 00:04:24,759
go. It works great on websites. Check it out fast tracks tube dot

54
00:04:24,800 --> 00:04:28,560
com. All right, today's episode, we have something submitted to me,

55
00:04:29,240 --> 00:04:34,600
and it looks like it's focusing on
the most common wiring method out there in

56
00:04:34,639 --> 00:04:41,439
the industry for residential You guessed it, non metallic sheet cable. So I'm

57
00:04:41,480 --> 00:04:45,720
gonna read the question and then I'll
go into a little a little more detail.

58
00:04:46,319 --> 00:04:49,279
Greetings, Paul. I love your
podcasts, love your videos. I

59
00:04:49,399 --> 00:04:54,040
love what you do for the industry. Keep up the good work. I've

60
00:04:54,040 --> 00:04:58,000
heard you talk from time to time
about how important it is to understand non

61
00:04:58,000 --> 00:05:01,319
metallic sheet cable, and many of
us in the field take it for granted.

62
00:05:01,920 --> 00:05:09,079
Can you please do a podcast explaining
all the important nuances of non metallic

63
00:05:09,160 --> 00:05:14,439
sheet cable and maybe even give us
some tidbits. I like that tidbits,

64
00:05:14,680 --> 00:05:18,360
tidbits of information that can help us
grow in the field, to become more

65
00:05:18,399 --> 00:05:23,959
knowledgeable. All my guys listen to
your podcasts every morning before we go to

66
00:05:24,000 --> 00:05:30,480
work. Keep them coming. Thanks
in advance. Okay, great, wonderful.

67
00:05:30,879 --> 00:05:35,199
I loved how that flowed. Very
good question, and it's very broad,

68
00:05:35,360 --> 00:05:39,279
all right, enough of that,
very broad, very broad because you're

69
00:05:39,279 --> 00:05:43,680
asking about nomata non metallic sheath cable. And you know what, if you're

70
00:05:43,759 --> 00:05:46,439
new to non metallic sheet cable or
you're like, what the hell is it,

71
00:05:46,279 --> 00:05:50,839
it is probably what's in your home. Okay, So go to somewhere

72
00:05:50,839 --> 00:05:55,279
in your home that is not covered
by sheet rock and you have some wearing

73
00:05:55,279 --> 00:05:59,040
in it. Unless you're dealing in
the nineteen forties and fifties or whatnot,

74
00:05:59,160 --> 00:06:03,240
chances are you're going to be having
nonmetallics sheet cable. It is a sheathing

75
00:06:03,879 --> 00:06:12,800
like an extrusion of PVC material over
top of individual conductors inside that can be

76
00:06:12,920 --> 00:06:17,639
flat or plexed means pre twisted,
and it is the most common wiring method

77
00:06:17,759 --> 00:06:25,639
used in the electrical industry for residential
applications and even light commercial applications. Remember,

78
00:06:26,120 --> 00:06:30,160
if you can build it out of
wood, then chances are you could

79
00:06:30,240 --> 00:06:34,800
use nonmetallic sheet cable at it.
Obviously, the caveat is check your local

80
00:06:34,920 --> 00:06:40,040
building rules and YadA, YadA,
YadA. But again, chances are if

81
00:06:40,079 --> 00:06:45,199
it's type three, four or five
construction, then you're okay to use nonmetallic

82
00:06:45,279 --> 00:06:47,879
sheet cable. So first of all, I guess let's kind of give a

83
00:06:47,920 --> 00:06:53,800
scope of non metallic sheet cable it. You know, many people refer to

84
00:06:53,839 --> 00:06:58,279
this as romax. Okay, So
that's something that makes it a little easier

85
00:06:58,279 --> 00:07:01,240
for you to remember or understand.
Now, Romax is a trademark of south

86
00:07:01,319 --> 00:07:06,920
Wire. Now Southwire is a leading
manufacturer of non metallic sheet cable. So

87
00:07:08,160 --> 00:07:15,240
is on Coal Wire Corporation. So
is zero right? So is? I

88
00:07:15,360 --> 00:07:21,199
think it's CME. So there's plenty
of manufacturers that make non metallic sheet cable.

89
00:07:21,240 --> 00:07:25,160
Now, all of these manufacturers,
okay, there's something that I always

90
00:07:25,199 --> 00:07:29,720
have to tell people. All of
these manufacturers make it to the same UL

91
00:07:29,800 --> 00:07:34,800
standard. So the UL standard that's
Underwriter's laboratory, there's an ant CUL standard

92
00:07:35,000 --> 00:07:41,519
that gives the manufacturers kind of the
guidelines on production. That way, there's

93
00:07:41,560 --> 00:07:47,279
a standardization we know it's safe,
and that's UL seven nineteen if you've never

94
00:07:47,399 --> 00:07:53,720
heard that before. Seven nineteen is
the kind of the the creation guide that

95
00:07:53,879 --> 00:07:59,199
all of the manufacturers use. So
essentially, all of the non metallic sheet

96
00:07:59,240 --> 00:08:03,560
cable that's produced, no matter who
it is, is the same. It

97
00:08:03,680 --> 00:08:09,639
works exactly the same. Now,
what differentiates is different? Does that work

98
00:08:09,800 --> 00:08:16,920
differentiass What differentiates companies is their level
of service that they provide additional assistance,

99
00:08:18,560 --> 00:08:24,399
how easily it is to obtain the
material cost factors, which usually should be

100
00:08:24,439 --> 00:08:28,319
about the same cost wise, because
copper is a commodity, right, so

101
00:08:28,519 --> 00:08:35,720
it kind of about the same.
But really they're all produced basically exactly the

102
00:08:35,840 --> 00:08:39,360
same. You know, some people
have their little nuances. No, this

103
00:08:39,480 --> 00:08:43,960
slides through the studs better than this
and that and again. In most of

104
00:08:43,000 --> 00:08:48,360
the time me is an electrician,
I end up saying that's bullshit. You

105
00:08:48,480 --> 00:08:52,519
know, it all pulls the same. Now, standards have changed a little

106
00:08:52,559 --> 00:08:56,759
bit, or the expectation has changed
a little bit, so you might see

107
00:08:56,799 --> 00:09:01,159
that no metallity cables a little stiffer
than it used to be. It's not

108
00:09:01,279 --> 00:09:05,159
as soft. That is due to
crushing impact and things that are changing in

109
00:09:05,200 --> 00:09:09,360
the industry. But they're still compliant
with seven nineteen, and all the manufacturers

110
00:09:09,360 --> 00:09:13,159
are are still on board. Okay, there's nobody being rogue out there,

111
00:09:13,240 --> 00:09:20,360
if you will. And so the
one thing that I always tell people that

112
00:09:20,600 --> 00:09:24,759
you know, Nomatology Cable is a
listed product. Okay, it's required to

113
00:09:24,799 --> 00:09:30,200
be listed by Dot six of the
NEC. Now, remember the ANEC is

114
00:09:30,200 --> 00:09:35,519
not an installation guide. Okay,
it's not for the untrained. But we

115
00:09:35,679 --> 00:09:39,960
know that if we install something in
compliance with the ANEC, that it is

116
00:09:39,039 --> 00:09:46,679
a minimum, a minimum safety standard. Right. I know, I know.

117
00:09:46,840 --> 00:09:50,720
I've got my haters out there who
say, Paul, it's not a

118
00:09:50,759 --> 00:09:54,440
minimum safety standards. Damn If it
isn't, it's a minimum. If you

119
00:09:54,559 --> 00:09:58,080
do it less than the n EC, you're gonna get failed rejected. And

120
00:09:58,399 --> 00:10:01,600
if I can you in a courtroom, I'm going to rip you apart because

121
00:10:01,639 --> 00:10:05,279
it's less than the threshold. So
it is a minimum standard. Those that

122
00:10:05,399 --> 00:10:11,240
say that it's not are just blowing
wind, blowing wind. It is a

123
00:10:11,279 --> 00:10:13,960
minimum standard. You have to achieve
it. Now, many people go beyond

124
00:10:15,120 --> 00:10:18,720
the minimum, and that's great,
you have that prerogative. But there's nothing

125
00:10:18,799 --> 00:10:22,320
wrong with those that meet the minimum. It's still compliant. It's still fine.

126
00:10:22,279 --> 00:10:26,440
But it is required to be a
listed product. And the article that

127
00:10:26,480 --> 00:10:31,840
we're talking about if you're in your
National Electrical Code is three thirty four,

128
00:10:31,799 --> 00:10:37,480
right, So article three thirty four
is what gives us the guidance are the

129
00:10:37,639 --> 00:10:41,559
minimum standards that we have to follow. And you know, if you're not

130
00:10:41,639 --> 00:10:46,279
familiar with working with the National Electrical
Code, it's it's an intimidating document for

131
00:10:46,360 --> 00:10:50,039
many people. It definitely is.
But once you learn the flow, the

132
00:10:50,159 --> 00:10:56,440
techniques and how things work, and
it becomes much easier to be able to

133
00:10:56,519 --> 00:11:00,039
maneuver that document, especially under a
stressful situation, maybe in the field the

134
00:11:00,120 --> 00:11:03,080
inspector's breathing down your neck, or
if you're preparing for an electrical exam.

135
00:11:03,240 --> 00:11:07,519
It does become easier the more you
work with it and use it. But

136
00:11:07,720 --> 00:11:11,960
Dots six, which is a section
within the article three thirty four, says

137
00:11:13,080 --> 00:11:16,799
that in M and NMC, now
the C deals with a corrosive environment.

138
00:11:18,159 --> 00:11:22,639
Most manufacturers don't make that product today, the NMC. They just use uf

139
00:11:22,960 --> 00:11:28,519
DA B as a alternative, right, and that's under three forty of the

140
00:11:28,639 --> 00:11:31,960
NBC, so it can be used
as an alternative to no metallic sheet cable.

141
00:11:33,039 --> 00:11:35,840
Got some rules you gotta follow,
but again it can it can be

142
00:11:35,879 --> 00:11:39,799
as an alternative, and that is
okay for corrosive environment, that type of

143
00:11:39,879 --> 00:11:46,919
thing. So nobody makes the NMC
really that I'm aware of, and I'm

144
00:11:46,960 --> 00:11:50,799
pretty intimate in the in that industry, so I can tell you I don't

145
00:11:50,799 --> 00:11:56,080
know of anybody that does that.
Okay. Now, the interesting thing that

146
00:11:56,159 --> 00:11:58,320
people ask me all the time,
so this is kind of answering these these

147
00:11:58,440 --> 00:12:05,120
questions, is where can I use
non metallic sheet cable? Well, if

148
00:12:05,159 --> 00:12:09,360
you go to dot ten, which
is the section within three thirty four,

149
00:12:09,240 --> 00:12:13,159
it will tell you where it's permitted. Now, this is not an all

150
00:12:13,200 --> 00:12:18,279
inclusive list, but this is you're
gonna have to work with you, HJ.

151
00:12:18,480 --> 00:12:22,120
But this is the most These are
the main lion share if you will,

152
00:12:22,440 --> 00:12:28,120
of locations or applications where non metallic
sheet cable is perfectly fine. And

153
00:12:28,200 --> 00:12:31,960
you'll see that there's five listed in
here, and it will cover some of

154
00:12:33,000 --> 00:12:35,440
these myths that people have. Okay. Number one it says one and two

155
00:12:35,480 --> 00:12:41,399
family dwellings and they're attached or detached
garages and they're storage building. So this

156
00:12:41,600 --> 00:12:45,279
allows you to use non metallic sheet
cable in a one family dwelling, each

157
00:12:45,399 --> 00:12:50,679
individual dwelling of a two family dwelling, okay, and to their detached garages

158
00:12:52,720 --> 00:12:56,480
right or attached garages. So again
people ask all the time, I've got

159
00:12:56,559 --> 00:13:00,720
my house, I'm doing it a
nonmetallic sheet cable, I'm build a garage

160
00:13:00,759 --> 00:13:05,720
out back. Can I wire it
in non metallogy cable? Absolutely you can.

161
00:13:05,600 --> 00:13:11,720
It's associated with the dwelling and three
thirty four dot ten, Item number

162
00:13:11,799 --> 00:13:16,200
one gives me that permission, so
it's no, it's not really a question,

163
00:13:16,759 --> 00:13:20,480
go for it. The next thing
is item number two, and it

164
00:13:20,559 --> 00:13:26,519
says multi family dwellings and their detached
garages are permitted. Garage is permitted to

165
00:13:26,559 --> 00:13:31,639
be type three, four or five
construction. So type three, four or

166
00:13:31,679 --> 00:13:37,600
five construction is associated with wood,
okay, whether it's heavy timber and type

167
00:13:37,679 --> 00:13:45,879
four either way, it is is
associated with a wood construction. So if

168
00:13:45,919 --> 00:13:50,600
the building is being built and it
is wood construction, like let's say a

169
00:13:50,679 --> 00:13:54,159
multifamily dwelling, maybe it's four stories
or five is sprinkled at, gotta be

170
00:13:54,240 --> 00:13:58,919
familiar with the building codes and that
or but if it's but if it can

171
00:13:58,039 --> 00:14:03,799
be built out of wood, then
most certainly the type of construction is going

172
00:14:03,840 --> 00:14:07,360
to be type three, four or
five. And if that's the case,

173
00:14:07,120 --> 00:14:11,759
non metallic products are fine even up
through the fourth and fifth floor. If

174
00:14:11,799 --> 00:14:15,600
it's sprinkled on the fifth floor,
if they're using wood, then you can

175
00:14:15,720 --> 00:14:18,879
use non metallic sheet cable. It's
perfectly fine. It's a listed product.

176
00:14:20,039 --> 00:14:22,639
Now, I know there's haters out
there who said, no, I gotta

177
00:14:22,679 --> 00:14:24,440
use MC or no, I'm gonna
pipe it all in, and I'm like,

178
00:14:24,559 --> 00:14:28,480
okay, whatever you can pound your
chest. Reality is, I am

179
00:14:28,519 --> 00:14:31,639
an electrician. If it permits me
to use non metallic sheet cable, and

180
00:14:31,679 --> 00:14:37,159
I can finish that job in a
three quarters of the time I'm using non

181
00:14:37,200 --> 00:14:39,799
metallic sheet cable. I'm making sure
that I bid at it. That okay.

182
00:14:41,799 --> 00:14:45,279
But at the end of the day, if it's a listed product,

183
00:14:45,399 --> 00:14:48,360
it works fine. It's been evaluated, it's been tested. You need to

184
00:14:48,440 --> 00:14:52,080
put it in undamaged, do everything
right, follow all the rules. In

185
00:14:52,120 --> 00:14:54,799
three thirty four, I'm good to
go, and so I can do any

186
00:14:54,840 --> 00:15:01,519
of those individual dwelling units. And
if I'm doing a multi family apartment complex

187
00:15:01,000 --> 00:15:07,039
and they have separate detached garage units
for each one of these apartments, then

188
00:15:07,159 --> 00:15:11,519
I can most certainly do them as
well in nonmeatoic sheath cable. That's what

189
00:15:11,559 --> 00:15:16,559
it tells me three three four ten
Item two. The third one says other

190
00:15:16,720 --> 00:15:20,320
structures permitted to be type three,
four or five constructions. So you can

191
00:15:20,519 --> 00:15:26,200
have an office building, you could
have a mini storage, you could have

192
00:15:28,240 --> 00:15:33,279
other types of things on office building. Okay, a local business that's being

193
00:15:33,399 --> 00:15:39,440
framed out of wood members, if
it's type three or four or Type three,

194
00:15:39,559 --> 00:15:45,480
four or five construction, then I
am most certainly can use a nonmetomic

195
00:15:45,559 --> 00:15:50,159
sheaf cable. Now, the only
caveat here is it when it's another structure

196
00:15:50,240 --> 00:15:52,000
other than what we just talked about
one and two family or multi family.

197
00:15:54,039 --> 00:15:56,799
Then it requires that those cables be
concealed within the floors, walls, or

198
00:15:56,879 --> 00:16:03,519
ceilings that provide a thermal barrier of
material that has at least a fifteen minute

199
00:16:03,559 --> 00:16:07,840
finish rating as identified in listing other
fire rated assemblies. And it gives you

200
00:16:07,840 --> 00:16:14,080
an informational note that'll kind of give
you that information NFPA two twenty. If

201
00:16:14,120 --> 00:16:17,159
you have link, you get it
free, right, I mean, well

202
00:16:17,440 --> 00:16:19,720
not free, but it's on the
app. So that's why I tell people

203
00:16:21,279 --> 00:16:26,000
as contractor I'm paying the one annually
just so I can have link. Because

204
00:16:26,159 --> 00:16:29,600
again I have I have the ability
to go to that NFPA two twenty and

205
00:16:29,759 --> 00:16:33,320
look, but that's typical sheet rock, drywall, gypsum would meet that,

206
00:16:34,039 --> 00:16:40,679
right, not a problem. So
and also just so you know, you

207
00:16:40,799 --> 00:16:45,279
have informed an annexe, right,
it's in your codebook, it's already there.

208
00:16:45,759 --> 00:16:48,399
And that annexe is also going to
give you a description of the different

209
00:16:48,440 --> 00:16:52,480
building types with type one, type
two, Type three, type four,

210
00:16:52,600 --> 00:16:56,799
type five or maybe type one AB
or two. Maybe it's it's kind of

211
00:16:56,919 --> 00:17:02,279
all there. But if you're not
a building person and you're not overly familiar

212
00:17:02,480 --> 00:17:07,599
with the building construction, you're just
electrician, you know, having to NFPA

213
00:17:07,680 --> 00:17:11,079
two twenty there to give you the
insight on the different types of building instructions

214
00:17:11,119 --> 00:17:14,599
can be beneficial. And again if
you have link, it's already there,

215
00:17:14,720 --> 00:17:18,480
so use it. But informative NXE
is a good start to get you there.

216
00:17:19,319 --> 00:17:22,920
For me, all I had to
do is find out what the building

217
00:17:22,319 --> 00:17:27,960
was being listed as in the permitting
and if it's type three, four or

218
00:17:29,039 --> 00:17:30,519
five and it was wood, then
I knew that I could use nonmetallic in

219
00:17:30,599 --> 00:17:34,920
my bid reflected that that type of
thing. So you know, all you

220
00:17:34,960 --> 00:17:38,240
gotta do is ask, do your
due diligence, and you'll find out whether

221
00:17:38,359 --> 00:17:42,200
or not you can or you can. But again, obviously it's going to

222
00:17:42,279 --> 00:17:47,640
be behind that fireberry or at least
fifteen minutes. So she rocked jips and

223
00:17:47,720 --> 00:17:52,400
things like that. I'd number four. And here's one that people question a

224
00:17:52,559 --> 00:18:00,039
lot is can I put non metallic
sheet cable in the cable trays? Well,

225
00:18:00,200 --> 00:18:07,079
I am number four says cable trays
in structures permitted to be type three,

226
00:18:07,200 --> 00:18:11,440
four or five again wood construction,
where the cables are identified for the

227
00:18:11,599 --> 00:18:15,200
use. Now, when we say
identified for the use, you gotta remember

228
00:18:15,240 --> 00:18:18,880
that not all non metallic sheath cables
printing on the outside of it. Remember

229
00:18:18,920 --> 00:18:22,400
the conductors don't need to be printed
on inside of non metallic sheath cable,

230
00:18:22,720 --> 00:18:26,920
but it has to be printed on
the sheathing. Okay, whether it's printed

231
00:18:26,000 --> 00:18:32,720
on it, dot matrix, embossed, whatever kind of melted into it,

232
00:18:33,240 --> 00:18:37,319
it has to be the information on
it. And if it doesn't say CT

233
00:18:37,599 --> 00:18:42,720
use on it, then you cannot
put it in a cable tray. Okay,

234
00:18:42,960 --> 00:18:47,279
you just you can't do it.
And not all non metallic sheet cables

235
00:18:48,720 --> 00:18:56,279
are marked for use in a cable
tray, right, So just keep that

236
00:18:56,359 --> 00:18:57,680
in mind. Now, if you
do go that route and you do have

237
00:18:57,880 --> 00:19:00,559
cable tray, you know they have
some of them that are used in these

238
00:19:00,640 --> 00:19:06,759
really large houses, they have a
cable tray system. It's also important to

239
00:19:06,799 --> 00:19:11,400
distinguish between what's called a cable tray
and a cable management system. Not all

240
00:19:11,480 --> 00:19:15,319
cable management systems are cable trays.
So you might be able to put your

241
00:19:15,400 --> 00:19:19,119
cables in a cable management system and
the only thing you have to worry about

242
00:19:19,160 --> 00:19:25,359
is bundling and making sure you're not
having a bundling issue, and they might

243
00:19:25,480 --> 00:19:30,240
not be cable trays, whereas you
have certain restrictions with cable trays you have

244
00:19:30,319 --> 00:19:33,079
to be aware of. Right.
So again, it's really important to identify

245
00:19:33,240 --> 00:19:37,279
the system that you're using. Don't
be afraid to reach out to the manufacturers

246
00:19:37,319 --> 00:19:41,839
of the system you're using, get
clarity, don't try to wing it on

247
00:19:41,920 --> 00:19:45,440
your own, be as don't be
afraid to reach out and ask people.

248
00:19:45,599 --> 00:19:48,519
That's all I'm saying. Okay,
don't have to be you know, kind

249
00:19:48,519 --> 00:19:51,440
of be humble in that we're just
trying to get the job done. That's

250
00:19:51,440 --> 00:19:56,400
all. The last one here is
one that people tend to question about is

251
00:19:56,480 --> 00:20:00,880
item number five. It says type
one and two con juction where installed within

252
00:20:02,039 --> 00:20:03,839
raceways for me to be installed in
type one type of good construction. So

253
00:20:03,920 --> 00:20:08,400
what does that mean? So you
might have type one and type two if

254
00:20:08,440 --> 00:20:11,920
you were to go back and look
at the construction that's typically stealing concrete,

255
00:20:14,119 --> 00:20:19,599
that type of thing as the predominant
type of construction, and it required the

256
00:20:19,680 --> 00:20:26,079
wiring methods to be like emt rigid, intermediate, whatnot. So people think

257
00:20:26,279 --> 00:20:33,920
that I couldn't put no metaged cable
and sleeve it in a raceway for some

258
00:20:33,119 --> 00:20:40,160
type of application where the wiring method
was required to be a raceway, but

259
00:20:40,400 --> 00:20:42,599
for some reason I wanted to sleeve
in a piece of nomatag sheed cable.

260
00:20:42,720 --> 00:20:47,680
That's perfectly okay under this rule.
And there's a lot of people that think,

261
00:20:47,759 --> 00:20:49,680
WHOA, you can't put no metallogy
cable in a raceway. That is

262
00:20:51,240 --> 00:20:57,200
not true. Not true. There's
many aspects of the NC where it talks

263
00:20:57,200 --> 00:21:04,000
about cables inside. We get we
get rules for raceway feel for cables treated

264
00:21:04,039 --> 00:21:08,400
as a single conductor, Chapter nine, Table one, and the various notes

265
00:21:08,480 --> 00:21:14,640
that are socia. There's mountains of
evidence that allows us to put a cable

266
00:21:14,839 --> 00:21:18,400
inside of a raceway. Even in
three thirty four, when we think that

267
00:21:18,480 --> 00:21:22,720
there's a possibility of physical damage,
then it directly allows us to put a

268
00:21:22,799 --> 00:21:26,440
cable inside of a raceway. So, and this is just another example where

269
00:21:26,440 --> 00:21:30,319
it's flat out telling you if it's
type one type two construction that happens to

270
00:21:30,359 --> 00:21:33,480
be what you're in, and you
happen to have a piece of non metallic

271
00:21:33,559 --> 00:21:37,160
sheet cable handy and you want to
use it, that's fine, perfectly,

272
00:21:37,319 --> 00:21:41,680
Okay, still has to be the
raceway that's designed for that type of building,

273
00:21:42,599 --> 00:21:45,599
But this directly allows you to be
able to put some non metallic in

274
00:21:45,720 --> 00:21:48,880
there if you need it to,
as long as again you follow raceway feel

275
00:21:49,039 --> 00:21:52,279
and all that stuff, unless it's
only for physical damage, and then the

276
00:21:52,400 --> 00:21:56,920
raceway feel kind of gets ignored for
that type of thing. But anyway,

277
00:21:56,960 --> 00:22:03,319
you get the point. Now,
those are the uses permitted, and then

278
00:22:03,400 --> 00:22:07,759
you get into what's called a breakdown
of additional items. There's a there's an

279
00:22:07,799 --> 00:22:11,480
A and a B. Now we
won't talk about B because that's NMC and

280
00:22:11,559 --> 00:22:15,039
nobody really makes NMC. Like I
said, that's where you're going to use

281
00:22:15,559 --> 00:22:18,880
UF for that UNDERGRAMD feeder and branch
an article three forty, you're gonna use

282
00:22:18,960 --> 00:22:22,640
that, and that's probably what most
people do because you're not gonna find NMC

283
00:22:22,880 --> 00:22:29,519
from anybody again, C being corrosive. Now A is type n M.

284
00:22:29,799 --> 00:22:33,880
You know, remember Type n M
also covers this new stuff called nmpcs.

285
00:22:34,640 --> 00:22:40,079
Okay, power control and signal all
in one cable assembly. That's still just

286
00:22:40,319 --> 00:22:45,160
NM cable. It's just it used
to be NMS right with an S on

287
00:22:45,240 --> 00:22:49,559
it, but a couple of cycles
ago we got rid of that. Then

288
00:22:49,640 --> 00:22:56,279
it's kind of funny because then that
was before we came out with the nmpcs,

289
00:22:56,559 --> 00:23:02,960
which is kind of part of my
patents for the mc PCs, and

290
00:23:03,039 --> 00:23:06,680
I have a bunch of patents for
that, but it came out with it

291
00:23:06,880 --> 00:23:10,200
also for the NM but is you
know, it's kind of pointless to try

292
00:23:10,240 --> 00:23:14,039
to patent that. I'm not worth
it. But the same kind of concept,

293
00:23:14,160 --> 00:23:18,920
whereas you have zero to ten volt
signal and control cable inside of the

294
00:23:18,960 --> 00:23:22,480
same cable assembly with the power and
in order to get that separation under seven

295
00:23:22,599 --> 00:23:26,759
twenty five of the NC, which
is signaling control, you have to have

296
00:23:26,799 --> 00:23:30,200
at least at thirty mills of sheathing
around your power conductors. Then that as

297
00:23:30,319 --> 00:23:36,680
acts as an adequate separation between the
six hundre volt rated insulation and then the

298
00:23:37,319 --> 00:23:41,400
conductors and all that are inside of
this lower voltage zero to ten volt control

299
00:23:41,480 --> 00:23:47,319
and signaling cable, So it allows
it to do this, but that also

300
00:23:47,440 --> 00:23:51,319
falls under NM okay, so you're
not going to see nmpcs here. If

301
00:23:51,359 --> 00:23:56,359
that's what you're using. It's just
all m right, you know. Nomatology

302
00:23:56,519 --> 00:24:00,920
cable again referred to by many people
as romex trade name for Southwire gum,

303
00:24:02,119 --> 00:24:07,440
but it's still just non metallic sheet
cable. It states the permitted use.

304
00:24:07,559 --> 00:24:12,559
It says it for both exposed and
concealed work in normally dry locations steps as

305
00:24:12,640 --> 00:24:18,759
prohibited in three through thirty four Dot
ten three and of course three was the

306
00:24:18,880 --> 00:24:25,359
applications for other structures, and those
applications okay, whereas obviously it can't be

307
00:24:25,440 --> 00:24:29,079
exposed because it said it had to
be behind what a fifteen minute fire rating,

308
00:24:29,119 --> 00:24:33,160
so that's why it makes that statement. But if you're not in other

309
00:24:33,279 --> 00:24:36,680
structures, you're in one family,
two family. People say, can I

310
00:24:36,839 --> 00:24:41,319
run non metallic sheet cable exposed?
Absolutely you can. I mean it specifically

311
00:24:41,480 --> 00:24:47,559
allows you to do it. Right
there in three thirty four dot ten A

312
00:24:48,319 --> 00:24:52,559
right says it in black and white. Now it is a dry location only

313
00:24:52,640 --> 00:24:57,119
product. So that brings me to
the next question that people ask me about

314
00:24:57,200 --> 00:25:02,559
installing it in crosspaces is in Look, I'm here to tell you that ninety

315
00:25:02,640 --> 00:25:04,440
nine percent of the crawl spaces that
I've ever been in, and I was

316
00:25:04,480 --> 00:25:08,240
from Virginia, I've been in my
share of crass spaces, they were dry

317
00:25:08,319 --> 00:25:14,079
locations. They were inside the building
envelope. There was no Brooker stream running

318
00:25:14,160 --> 00:25:18,680
through the crawl space. You know
what you have to look at is if

319
00:25:18,720 --> 00:25:22,079
you're in that crawl space and you
have regular floor joists that you see above

320
00:25:22,119 --> 00:25:26,720
you, you have regular insulation,
all this type of then you've got a

321
00:25:26,799 --> 00:25:30,640
dry location. Now I get it. HJ can make whatever ruling they want.

322
00:25:30,799 --> 00:25:36,640
People can sit there and say,
well, humidity and moisture whatever.

323
00:25:37,319 --> 00:25:38,599
I mean. I could say the
same thing about a bathroom, but I

324
00:25:38,680 --> 00:25:42,440
can promise you that the light over
the vanity does not have to be wet

325
00:25:42,519 --> 00:25:48,880
location rated or damp location rated just
because it's in the bathroom. You get

326
00:25:48,920 --> 00:25:52,839
me get you feel when I'm laying
down. So anybody can let their mind

327
00:25:52,920 --> 00:25:57,079
wander if they want to. But
the majority of the crawl spaces that I

328
00:25:57,240 --> 00:26:03,319
have been involved in, I can
honestly say that I would not call them

329
00:26:03,160 --> 00:26:07,480
a wet location. Whether it's a
damp puddle in there or not, that

330
00:26:07,559 --> 00:26:11,880
doesn't mean that it's all of a
sudden going to jump up and the cable

331
00:26:11,000 --> 00:26:14,400
is going to be submerged in it
or whatever. You know what I'm saying.

332
00:26:15,119 --> 00:26:18,480
And if I look around and I've
already see that it's not treated flooring,

333
00:26:18,720 --> 00:26:25,880
it's not it's within the building envelope, if you will, then I

334
00:26:26,160 --> 00:26:30,680
at the end of the day,
I have a hard time believing that that

335
00:26:30,720 --> 00:26:37,079
would be anything other than a dry
location. I'm just saying again, you

336
00:26:37,200 --> 00:26:40,960
have to deal with your HJ and
sometimes the minds can wander and they can

337
00:26:41,039 --> 00:26:45,559
think what they want, but that's
the reality of it. The next item

338
00:26:45,200 --> 00:26:52,160
that's permitted is that in him can
be installed or fished in air voids in

339
00:26:52,240 --> 00:26:57,519
masonry, block or tile walls.
So there is occasion where the blocking in

340
00:26:57,599 --> 00:27:03,319
your wall might be a great path, not in new construction because you would

341
00:27:03,359 --> 00:27:07,880
not fish it in new construction.
You would not install it in these voids

342
00:27:07,920 --> 00:27:14,559
because you couldn't meet the securing and
supporting requirements of DOT thirty. But is

343
00:27:14,640 --> 00:27:18,680
it allowed to be done? Sure? So I'm coming back to do some

344
00:27:18,799 --> 00:27:23,440
remodeling, some retro work or something
like that, and I need to get

345
00:27:23,559 --> 00:27:30,200
into these air voids for masonry block
or maybe it's a tile wall, and

346
00:27:30,240 --> 00:27:33,519
I need to fish it from A
to B. Hopefully you're electrician, you

347
00:27:33,599 --> 00:27:36,440
know what we're talking about. Fishing, not with a fly rod, not

348
00:27:36,559 --> 00:27:38,920
out on the lake, but you
know what I mean. Then it's perfectly

349
00:27:40,039 --> 00:27:44,960
okay. Now, the code doesn't
give a distance that people ask me,

350
00:27:45,480 --> 00:27:48,319
not so much about NM cable,
but asking me about the phishing allowance for

351
00:27:48,480 --> 00:27:51,960
MC for example, and they say, well, what's the maximum distance?

352
00:27:52,759 --> 00:27:56,799
Well, the code doesn't give you
a maximum distance. It's kind of a

353
00:27:56,880 --> 00:28:00,720
common sense thing. This is not
an installation guide, you know. But

354
00:28:03,759 --> 00:28:07,279
you are allowed to fish it in
those voids. Now, you gotta remember

355
00:28:07,000 --> 00:28:11,200
that even when you do this,
you're not going to fish it in these

356
00:28:11,319 --> 00:28:17,359
voids that are on a wall that's
subject to moisture and dampness. And all

357
00:28:17,400 --> 00:28:19,200
that type of stuff. So again
you still have to maintain that this is

358
00:28:19,319 --> 00:28:22,920
a dry location. And people say, well, Paul, I don't see

359
00:28:23,079 --> 00:28:26,960
that in that rule, but that's
going to be picked up in the US

360
00:28:27,079 --> 00:28:30,559
is not permitted, so don't worry. So I'm just saving you a little

361
00:28:30,599 --> 00:28:36,200
grief from being inspection issues. Right. So those are uses pretty now.

362
00:28:37,440 --> 00:28:41,880
Dot twelve of three thirty four is
uses not permitted, uses not permitted.

363
00:28:41,880 --> 00:28:45,359
It is not an all inclusive list. It's going to be again subject to

364
00:28:45,559 --> 00:28:51,880
the h J, but it is
the most common applications and we'll just go

365
00:28:51,960 --> 00:28:55,960
over them really quickly. Item number
one says in any dwelling or structure that's

366
00:28:56,000 --> 00:29:00,119
not specifically permitted and three thirty four
dot ten one, two, three and

367
00:29:00,240 --> 00:29:03,680
five that's what we talked about.
If it's a dwelling or structure that's it's

368
00:29:03,759 --> 00:29:07,920
one of those that we permitted one
family, two family, multi family,

369
00:29:08,839 --> 00:29:17,079
and other structures as long as it's
behind fifteen minutes. If there's any other

370
00:29:17,240 --> 00:29:22,200
dwelling or structure that would fall under
this that is not covered by what we

371
00:29:22,319 --> 00:29:26,599
just talked about in three thirty four
dot ten, then you could not use

372
00:29:26,640 --> 00:29:30,119
nonmetallog sheet cable. You just can't
use it, use something else right straightforward.

373
00:29:32,079 --> 00:29:33,880
People get confused in this and I'm
just going look, is all you

374
00:29:33,960 --> 00:29:38,720
gotta do is is your dwelling or
structure is it meeting three thirty four dot

375
00:29:38,759 --> 00:29:41,799
ten, one two, three and
five. If the answer is yes,

376
00:29:44,160 --> 00:29:48,240
then you can use nonmetallicg sheet cable. If the answer is no, then

377
00:29:48,359 --> 00:29:53,839
you can't use nomatology cable. Should
be pretty straightforward. Also non metallic shet

378
00:29:53,839 --> 00:29:57,240
cable. I do't Number two is
it can't be exposed within a dropped or

379
00:29:57,279 --> 00:30:03,000
suspended ceiling cavity in other than one
and two family and multi families. Okay,

380
00:30:03,519 --> 00:30:10,359
so basically commercial. Fine, And
this is where it brings me.

381
00:30:10,680 --> 00:30:14,839
Commercial. No, you can't use
it or get it. Fine, you

382
00:30:14,880 --> 00:30:18,440
can't use it in commercials above dropped
or suspended ceilings, but one and two

383
00:30:18,519 --> 00:30:26,000
family and multi family dwellings. The
actual dwelling unit we can if it has

384
00:30:26,039 --> 00:30:27,839
a drop ceiling. Now here's where
I get a lot of questions about what

385
00:30:27,920 --> 00:30:34,519
if it's an apartment complex in the
common halls are drop ceiling, then no,

386
00:30:34,839 --> 00:30:38,319
that's not the dwelling unit. That's
the common hall that falls on the

387
00:30:38,400 --> 00:30:41,640
commercial side. Of the building.
So no, you couldn't use it in

388
00:30:41,720 --> 00:30:45,799
above those drop ceilings, but you
could inside the individual dwelling units perfectly fine

389
00:30:47,039 --> 00:30:51,680
for that. At a number three
service entrance cable, obviously you can't use

390
00:30:51,720 --> 00:30:52,920
it in for service entrance cable.
I mean, why would you. It

391
00:30:53,039 --> 00:30:56,960
only goes up to a certain size
anyway, it's not really applicable to the

392
00:30:56,039 --> 00:30:59,839
installations. So that's common sense,
So you wouldn't use it as service.

393
00:31:00,160 --> 00:31:03,559
And we've got so many other options
we you know. The next is in

394
00:31:03,640 --> 00:31:08,880
commercial garages having a hazardous classified locations
as divined in five eleven dot thirteen.

395
00:31:08,960 --> 00:31:12,960
So obviously you're not going to use
it in a commercial garage. Makes sense

396
00:31:14,839 --> 00:31:18,279
obviously if it's hazardous classified locations,
a no brainer. The next one,

397
00:31:18,400 --> 00:31:23,480
number five in theaters or similar locations
except where permitted in five eighteen dot four

398
00:31:23,559 --> 00:31:27,240
c. So you're not going to
use it in the portions of the theater

399
00:31:29,039 --> 00:31:33,400
or similar that are places of assembly. Okay, we'll have over a hundred

400
00:31:33,440 --> 00:31:36,599
people and that type of thing.
You're not going to do that. But

401
00:31:36,640 --> 00:31:40,559
when it makes reference except as permitted
in five eighteen dot fourteen. See,

402
00:31:40,599 --> 00:31:45,720
now you do have some areas that
are maybe administrative some other areas of this

403
00:31:45,880 --> 00:31:51,599
place of assembly that that are not
going to meet that hundred over one hundred

404
00:31:51,599 --> 00:31:56,000
person threshold. That are maybe just
the offices for maybe the clergy or maybe

405
00:31:56,079 --> 00:32:01,920
an office manager or whatnot. That's
different. So you could have a building

406
00:32:02,000 --> 00:32:07,720
that has, you know, different
classifications all within the same building, and

407
00:32:07,799 --> 00:32:10,960
the places of assembly under five eighteen
is going to have certain wiring methods that

408
00:32:10,960 --> 00:32:17,960
are permitted there, but you could
have outside of that area again just offices

409
00:32:19,039 --> 00:32:22,359
that are framed up in wood.
No problem with using no metallic sheet cable

410
00:32:22,400 --> 00:32:27,119
in those areas, Okay, so
you might have to use two different wire

411
00:32:27,200 --> 00:32:32,839
methods for them. The next one
is motion picture studios. Obviously can't use

412
00:32:32,920 --> 00:32:39,240
it there. Storage battery rooms again, possible vapors and corrosive caustic things can't

413
00:32:39,279 --> 00:32:45,640
be in there. Eight in hoist
ways or on elevators or escalators, no

414
00:32:45,799 --> 00:32:52,599
brainer. Nine embedded and poured concrete, cement or aggregate. I do get

415
00:32:52,640 --> 00:32:57,640
this question a lot. Can you
embedded Obviously you can't put nomatadic sheet cable

416
00:32:57,680 --> 00:33:04,440
in the ground, but also obviously
can't embedded in cement, concrete aggregate.

417
00:33:04,559 --> 00:33:07,960
That just yeah, you should know
that by now you just can't do that.

418
00:33:07,640 --> 00:33:15,200
And at number ten obviously hazardous classified
locations except where specifically permitted by other

419
00:33:15,319 --> 00:33:17,599
articles in this code. Again,
it might be you have an area,

420
00:33:19,480 --> 00:33:22,720
let's say you have an aircraft hangar, and then you have an adjacent room

421
00:33:22,839 --> 00:33:29,759
or adjacent area that is, you
know, not part of the classified it's

422
00:33:29,759 --> 00:33:35,680
a non classified area. And you
have whatever in place to create that non

423
00:33:35,759 --> 00:33:40,200
classified area, whether it's exchanges of
air ventilation, positive ventilation or positive pressure

424
00:33:40,319 --> 00:33:45,400
or whatever, whatever, it's an
unclassified area. And if it's framed up

425
00:33:45,480 --> 00:33:50,759
wood and all that, then it's
probably going to meet the allowances in three

426
00:33:50,839 --> 00:33:55,160
thirty four dot ten probably three other
structures, and it's probably going to be

427
00:33:55,240 --> 00:34:00,519
in the walls behind the sheet rock
fifteen fifteen minute fire rating. Then you're

428
00:34:00,559 --> 00:34:04,079
good to go. So it's so
important to understand these things. And I

429
00:34:04,200 --> 00:34:10,280
think non metallic she cable is so
misunderstood, so misunderstood one of the things

430
00:34:10,320 --> 00:34:15,599
that I think about about non metallic
cable in general. And I kind of

431
00:34:15,639 --> 00:34:19,199
throw this out to a little tip
because this is libable to be a long

432
00:34:19,320 --> 00:34:22,960
podcast, and I get it people
don't like my long podcasts. I'm sorry,

433
00:34:23,519 --> 00:34:27,239
but I don't do multiple takes.
Y'all know me. I've been doing

434
00:34:27,280 --> 00:34:30,800
this thirty two years. I'm probably
the one of the only educators in the

435
00:34:30,880 --> 00:34:35,559
country who would just turn the mic
on and just start talking code. I

436
00:34:35,639 --> 00:34:37,079
don't need to rehearse, I don't
need to study. I don't need to

437
00:34:37,119 --> 00:34:40,559
do multiple takes. If it comes
out of my mouth, I believe it.

438
00:34:42,480 --> 00:34:45,400
You can agree to disagree. I
don't. I don't waste time on

439
00:34:45,440 --> 00:34:52,079
the bullshit. I give you the
facts, and I've got so much up

440
00:34:52,159 --> 00:34:55,159
in this wicked head that I just
try to give as much as I can,

441
00:34:55,960 --> 00:34:59,960
and sometimes I never know where to
start. It doesn't make me great

442
00:35:00,119 --> 00:35:01,920
than anybody else. Look, don't
it's not a holier than that thing.

443
00:35:02,000 --> 00:35:06,320
Folks. Don't. Please don't be
hitting the thumbs down because of that,

444
00:35:06,360 --> 00:35:07,920
Because I got that one guy who
thumbs down, and I know who he

445
00:35:08,000 --> 00:35:12,159
is because I can see him every
time he does it. I guess he

446
00:35:12,199 --> 00:35:14,960
doesn't have a YouTube channel because he
doesn't know I can see those things.

447
00:35:15,039 --> 00:35:20,760
But anyway, I see it,
and that's fine. But I tell you

448
00:35:20,880 --> 00:35:24,400
these things because it's just the facts, the facts. I don't have to

449
00:35:24,639 --> 00:35:30,360
edit stuff that doesn't make me smarter
than anybody, Absolutely not. You know,

450
00:35:30,480 --> 00:35:35,400
Mike Coult's probably forgotten more stuff than
I know. Okay, Ryan Jackson's

451
00:35:35,440 --> 00:35:38,280
probably forgotten more stuff than I know. I don't know. But I do

452
00:35:38,440 --> 00:35:40,320
my best to give you what I
can give you. And I'm a one

453
00:35:40,400 --> 00:35:43,920
take guy. I don't like to
do multiple takes of any damn thing.

454
00:35:43,960 --> 00:35:46,519
I don't have the time for that. Because some people can appreciate that.

455
00:35:46,639 --> 00:35:52,320
Some people can. But one of
the little tidbits the things that I tell

456
00:35:52,400 --> 00:35:54,960
people is when you think about non
metallicy cable and you think about how important

457
00:35:54,960 --> 00:35:59,000
it is to the industry, how
many of you know what the dash B

458
00:35:59,199 --> 00:36:02,360
means when you go by non metallic
sheet cable and you know the NM,

459
00:36:04,280 --> 00:36:06,880
but do you know what the dash
B? And if you're the select few

460
00:36:06,920 --> 00:36:12,880
out there who know what the dash
B is, kudos to you because you

461
00:36:12,960 --> 00:36:16,960
know, at the end of the
day, it's amazingly important, amazingly important.

462
00:36:17,679 --> 00:36:21,679
So let me let me kind of
tell you the history here. The

463
00:36:21,800 --> 00:36:27,760
dash B came about in nineteen eighty
four. It was an effort to that

464
00:36:27,920 --> 00:36:31,960
you will put together. It was
an effort because we had issues of insulation

465
00:36:32,400 --> 00:36:38,960
on the conductors that were inside of
the older type of NM being only rated

466
00:36:39,039 --> 00:36:43,480
sixty degrees C. Now you all
know that today you still can't exceed the

467
00:36:43,559 --> 00:36:46,599
ampacity values of sixty degree even though
you can use a ninety to adjusting correct

468
00:36:46,639 --> 00:36:53,960
and I'll explain why. Back then, what was happening is luminaires were expanding

469
00:36:54,599 --> 00:36:59,639
more wattage. People wanted more lighting, more intricate. People were putting up

470
00:36:59,679 --> 00:37:02,159
luminates. It had that insulation in
their People were ripping out the insulation.

471
00:37:02,599 --> 00:37:07,840
Anyway, heat rises, and you
were having problems with the transition between the

472
00:37:07,000 --> 00:37:12,920
leads from luminaires to the existing building
wire which was rated sixty and the new

473
00:37:13,000 --> 00:37:19,280
wires and leads were rated ninety.
And anyway, the breakdown was coming from

474
00:37:19,320 --> 00:37:23,840
the wiring that was part of the
dwelling at the time created problems. So

475
00:37:24,159 --> 00:37:31,920
the industry changed. In the dash
be simply signifies that the insulation on those

476
00:37:32,000 --> 00:37:37,400
conductors that are inside of that sheathing, no matter who the manufacturer is.

477
00:37:37,440 --> 00:37:42,800
By the way, the insulation on
those conductors are rated ninety degrees C.

478
00:37:44,599 --> 00:37:51,800
Now you can only use that ampacity
on table three ten sixteen for that ninety

479
00:37:51,840 --> 00:37:58,800
degrees C for the adjustment or corrective
purposes. Okay, so if you have

480
00:37:59,039 --> 00:38:05,000
four more current conductors, you're using
three ten fifteen C one, then you're

481
00:38:05,039 --> 00:38:10,719
gonna do You're gonna do an adjustment. If you have an ambient temperature that

482
00:38:10,960 --> 00:38:15,239
is other than thirty degrees celsius eighty
six degrees fahrenheit, you're gonna use three

483
00:38:15,320 --> 00:38:24,760
ten fifteen B one one table.
So what's significant for people is they talk

484
00:38:24,800 --> 00:38:32,360
about bundling and the importance of having
that dash B is so important because it

485
00:38:32,440 --> 00:38:37,760
allows me to do an adjustment or
a correction from a higher level of ampacity.

486
00:38:38,920 --> 00:38:45,639
So if I've got there's a picture
I posted on I think it's LinkedIn.

487
00:38:45,119 --> 00:38:50,079
No sorry, sorry sorry. I
posted on TikTok, and I don't

488
00:38:50,079 --> 00:38:55,119
do a lot on TikTok weird little
platform. But I posted on TikTok and

489
00:38:55,159 --> 00:39:00,000
I posted on Instagram the two vertical
platforms, and I do less of anything

490
00:39:00,039 --> 00:39:02,039
thing on but I you know,
they know people seem to be very active

491
00:39:02,079 --> 00:39:06,920
on those, so I posted two
questions. The feedback I got from people

492
00:39:07,039 --> 00:39:12,519
is really all over the place.
Only very few called out the actual issue

493
00:39:12,599 --> 00:39:19,280
that was in the picture, which
is a supporting issue but I got a

494
00:39:19,320 --> 00:39:22,840
lot of people call out the bundling, and I wanted to explain to people.

495
00:39:23,239 --> 00:39:29,039
One of the things to remember is
that when you have the non metallic

496
00:39:29,119 --> 00:39:35,079
sheet cable, you could have up
to nine current carrying conductors and still be

497
00:39:35,400 --> 00:39:43,679
okay. So you could have four
twelve twos bundled together, even if it's

498
00:39:43,800 --> 00:39:47,320
more than twenty four inches bundled together, and it's still gonna be okay for

499
00:39:47,360 --> 00:39:52,960
a twenty amp over current device.
If you didn't have that dash b then

500
00:39:53,000 --> 00:39:58,760
you would have to do that adjustment
from the sixty degree column, and if

501
00:39:58,800 --> 00:40:02,519
you did that, you're gonna end
up with conductor it's not worth anything,

502
00:40:04,679 --> 00:40:07,480
and you're gonna have to jump up
in size. But the importance of that

503
00:40:07,559 --> 00:40:10,679
dash fee means I can start from
the ninety So let me give you an

504
00:40:10,719 --> 00:40:15,880
example. Let me give you an
example. Twelve two under three ten sixteen

505
00:40:16,119 --> 00:40:21,039
under the ninety degree column is thirty
am peers. Now, we all know

506
00:40:21,199 --> 00:40:24,960
it's twelve gauge. It's good for
twenty small conductor rules to forty four D

507
00:40:25,199 --> 00:40:30,400
protects it at twenty. We all
get it. We know that. But

508
00:40:30,519 --> 00:40:35,679
if you look at three thirty four
eighty, it tells you that you're permitted

509
00:40:35,679 --> 00:40:38,440
to use the ninety for adjustment of
corrective purposes as long as the end value

510
00:40:38,480 --> 00:40:42,639
doesn't exceed that of the sixty degree. So all we're trying to do is

511
00:40:42,679 --> 00:40:45,840
to make sure that after that adjustment
of correction, which is basically a condition

512
00:40:45,880 --> 00:40:51,880
of use, whatever you're placing the
cable in a certain condition, whether it's

513
00:40:51,880 --> 00:40:57,000
ambient temperatures or a certain number of
current current conductors, will it still have

514
00:40:57,159 --> 00:41:02,000
the ability to handle the load in
question, or is it going to be

515
00:41:02,159 --> 00:41:05,679
equal to or greater than what's in
the six augree column. So that we

516
00:41:05,719 --> 00:41:07,679
don't have to do anything different,
we can just follow our normal plan and

517
00:41:07,719 --> 00:41:13,920
our normal sizing. Everything we normally
do. Well, if you think about

518
00:41:14,000 --> 00:41:22,199
this, if I have four NMB's
stacked bundled, if they're bundled, okay,

519
00:41:22,920 --> 00:41:28,559
more than twenty four inches bundled.
Let's say and I go to three

520
00:41:28,679 --> 00:41:32,599
ten fifteen C one, and you'll
notice that when you have this case,

521
00:41:32,639 --> 00:41:36,280
will be four cables, two conductors
in it, a black and a white,

522
00:41:36,320 --> 00:41:39,199
both are current current conductors. In
this scenario, that's eight current current

523
00:41:39,239 --> 00:41:43,679
conductors. Then I'm going to be
reducing it by seventy percent, okay.

524
00:41:45,039 --> 00:41:49,239
So you look at it that way
and you go, okay, if I'm

525
00:41:49,280 --> 00:41:53,280
producing it up to seventy percent,
because the eighty percent four to six and

526
00:41:53,599 --> 00:41:59,719
things like that, I believe I'm
going off memory up. So if it's

527
00:42:00,280 --> 00:42:02,639
by seventy percent, basically you're dropping
it thirty percent. So we say seventy

528
00:42:02,679 --> 00:42:09,280
percent de man factor, it's really
reducing it thirty percent. So if I

529
00:42:09,400 --> 00:42:15,119
took the thirty and I'm multiplied by
seventy percent, okay, then that gives

530
00:42:15,159 --> 00:42:21,360
me twenty one amps. So those
conductors, even though they're bundled, because

531
00:42:21,440 --> 00:42:25,159
of the benefit of starting at the
higher ampacity, because that insulation can handle

532
00:42:25,199 --> 00:42:30,719
a higher ampacity, it's still good
for twenty one amps. Well, that

533
00:42:30,800 --> 00:42:34,159
means I can totally ignore anything and
say, look, it's a twelve gage.

534
00:42:34,519 --> 00:42:37,880
It can be protected at twenty amps, and I can focus on the

535
00:42:37,920 --> 00:42:39,599
load and I don't have to worry
about it. Even if I've got four

536
00:42:39,639 --> 00:42:45,000
cables bundled together, I'm perfectly fine. If I did not have that dash

537
00:42:45,039 --> 00:42:51,599
B or that didn't come into play
back in nineteen eighty four, then I

538
00:42:51,639 --> 00:42:57,039
would be starting from a lower value
twenty amps. Under the sixty. If

539
00:42:57,079 --> 00:43:00,360
you do twenty times seventy percent,
that drops it down to fourteen amps.

540
00:43:02,679 --> 00:43:06,519
I'd be damn if I'm gonna have
a conductor that's supposedly good for twenty amps

541
00:43:06,519 --> 00:43:08,239
and all I can do is only
now it's only good for fourteen as because

542
00:43:08,239 --> 00:43:13,280
of bundling, which just means I'm
gonna have to bump up the size of

543
00:43:13,320 --> 00:43:16,760
the cable and the conductors. So
dash B is a beautiful thing, and

544
00:43:16,840 --> 00:43:22,440
I think people overlook that in the
industry and they don't understand the significance of

545
00:43:22,559 --> 00:43:27,000
it. And so that's kind of
the history, a little tidbit for you

546
00:43:27,360 --> 00:43:30,400
that explains the importance of that dash
B in the everyday life. That what

547
00:43:30,559 --> 00:43:35,360
you do because you because you are
going to be installing these cables in insulation,

548
00:43:36,639 --> 00:43:38,679
you're going to run into a bundling
situation. As long as you keep

549
00:43:38,719 --> 00:43:43,440
it to nine current carrying conductors or
less, whether it's ten gage, twelve

550
00:43:43,519 --> 00:43:46,639
gage, fourteen gays, and you're
gonna still be okay, right, still

551
00:43:46,679 --> 00:43:51,880
gonna be okay. Just keep it
to nine current carry conductors, maybe a

552
00:43:51,920 --> 00:43:57,440
fourteen three and three fourteen twos or
you know, four fourteen twos. You

553
00:43:57,519 --> 00:44:00,079
know whatever, just keep it to
nine or less then you're gonna be okay.

554
00:44:00,599 --> 00:44:05,480
Okay. So that's kind of the
history of the dash B. That's

555
00:44:05,480 --> 00:44:07,800
the importance of the dash B.
And again, I just wanted to make

556
00:44:07,840 --> 00:44:09,199
sure I threw that little tidbit out
there, whether you like it or not.

557
00:44:09,320 --> 00:44:14,639
And that's sorry I had to throw
it forty something minutes into the podcast.

558
00:44:14,719 --> 00:44:17,239
But hey, those that listen,
those that watch, get a benefit.

559
00:44:17,920 --> 00:44:22,960
Now when we talk about exposed nomatolic
sheet cable, people say, oh,

560
00:44:22,360 --> 00:44:25,679
can it be exposed? Can it
be exposed? Absolutely, it can

561
00:44:25,840 --> 00:44:32,679
be, but it has to follow
the surface of the building structure means following

562
00:44:32,760 --> 00:44:37,559
the framing, or on a running
board means you run it a flat running

563
00:44:37,599 --> 00:44:39,840
board and you actually mount it to
that, so it is actually running with

564
00:44:39,960 --> 00:44:45,000
the running board. That's all covered
in three thirty four fifteen exposed work.

565
00:44:45,480 --> 00:44:49,880
Now, if there is an area
where it makes it subject to physical damage,

566
00:44:49,880 --> 00:44:53,199
and again very subjective because we don't
have any definitions of what that is.

567
00:44:53,440 --> 00:44:57,800
We have no definitions of physical damage. Nobody's presented it. It's been

568
00:44:58,000 --> 00:45:02,119
it's well, it's been presented to
the code panel, but it's always rejected

569
00:45:04,639 --> 00:45:07,199
in the code we talk about physical
damage, severe physical damage, and so

570
00:45:07,400 --> 00:45:14,719
far it's just nobody I guess has
submitted something that makes the code panel happy

571
00:45:14,840 --> 00:45:20,400
enough to accept it as as part
of a minimum standard. Yet so again,

572
00:45:20,599 --> 00:45:24,480
AHJ's have to have to be the
ruling here and make that call.

573
00:45:25,239 --> 00:45:30,280
But if you're going to be installing
it in somewhere where you know somebody rules

574
00:45:30,320 --> 00:45:36,480
it's subject physical damage, then it
clearly states in three thirty four fifteen B

575
00:45:37,599 --> 00:45:40,840
the different wiring methods that you can
install it in. So again, for

576
00:45:40,920 --> 00:45:46,840
anybody that says you can't install noomatology
cable in a race way poppycock? Can

577
00:45:46,920 --> 00:45:52,039
I use poppycock? Is that is
that today? But yeah, it's it's

578
00:45:52,360 --> 00:45:59,079
you can perfectly okay to do so. Also, it is perfectly okay to

579
00:45:59,280 --> 00:46:04,960
install it in under unfinished basements and
in cross bass. You just have to

580
00:46:05,079 --> 00:46:08,840
follow all of the rules that are
given to you in three thirty four dot

581
00:46:08,920 --> 00:46:15,280
fifteen C. Okay, And I
sat Ryan people, I am in the

582
00:46:15,360 --> 00:46:20,679
twenty twenty three edition of the Nationalgical
Code. Anybody ever asked what edition are

583
00:46:20,679 --> 00:46:23,320
you in? If you don't tell
me when you submit something, I'm always

584
00:46:23,360 --> 00:46:27,760
going to go to the latest edition, right, always going to go to

585
00:46:27,840 --> 00:46:34,000
the latest edition. Right, let's
see your I hope I'm answering all the

586
00:46:34,119 --> 00:46:37,000
questions that people that you know,
kind of want to talk about. The

587
00:46:37,079 --> 00:46:40,679
next thing that people ask me about
no metallic sheet cable is is there a

588
00:46:40,800 --> 00:46:45,599
bending radius? And obviously those that
are familiar with the dot twenty four of

589
00:46:45,760 --> 00:46:53,440
most of the wiring cable I shouldn't
said wiring cable cable articles know that that's

590
00:46:53,519 --> 00:46:58,679
pretty much the area where you're going
to see bending radius minimums maintained bending radius.

591
00:46:59,320 --> 00:47:04,440
And so that's now exception for no
metallic sheet cable. The radius of

592
00:47:04,519 --> 00:47:10,280
the inner curve, of the inner
edge or the bin it shall not be

593
00:47:10,480 --> 00:47:15,920
less than, okay, less than
five times a diameter or the cable it

594
00:47:16,039 --> 00:47:21,360
bending at any tighter than that causes
the conductor's inside of it to have one

595
00:47:21,519 --> 00:47:27,000
side of the cable crinkle up.
We call it caterpillaring. And then the

596
00:47:28,079 --> 00:47:34,000
outer edge of it gets elongated and
it weakens the insulation. Okay, and

597
00:47:34,159 --> 00:47:37,159
in black insulation will happen as it'll
get opaque or you can see where it's

598
00:47:37,199 --> 00:47:40,519
kind of been stressed and damaged.
Might not have cracked, but it's stressed

599
00:47:40,559 --> 00:47:46,440
man, and that's going to affect
the reliability of the insulation. Yeah,

600
00:47:46,480 --> 00:47:52,920
I remember the insulations. The conductor
can handle way more current probably than what

601
00:47:52,039 --> 00:47:59,079
we list in table three ten sixteen, But it's the insulation that is the

602
00:47:59,159 --> 00:48:01,119
de volatile part. And if you
break down that insulation, everything else goes

603
00:48:01,159 --> 00:48:07,840
to crap. Okay, everything else
goes to crap. Now, when thinking

604
00:48:07,880 --> 00:48:10,159
about that five times the diameter of
the cable, and it has to be

605
00:48:10,199 --> 00:48:15,840
at least that that creates kind of
a more uniformed bend. There is now

606
00:48:16,000 --> 00:48:20,280
guidance in twenty twenty three because people
said, well, do you use the

607
00:48:21,119 --> 00:48:27,280
width or the diameter the flat part
or the major or minor portion of the

608
00:48:27,360 --> 00:48:30,840
cable. There's two different values when
it comes to a flat cable like a

609
00:48:30,920 --> 00:48:34,599
fourteen two flat with black white and
and equipment ground. So you have the

610
00:48:34,679 --> 00:48:37,679
long dimension in a side short dimension
when you're trying to come up with that

611
00:48:38,079 --> 00:48:43,639
five times. And they clarified this
in the twenty twenty three code. It

612
00:48:43,800 --> 00:48:49,159
says for flat cables, the major
diameter dimension of the cables shall be used,

613
00:48:49,239 --> 00:48:52,320
and that's the widest part. That's
the major diameter of the dimension.

614
00:48:52,440 --> 00:48:57,960
For the cable shall be used to
determine the bending rays. So you're obviously

615
00:48:59,039 --> 00:49:02,679
this makes sense from a manufacturer of
iron cable. The more that we can

616
00:49:02,760 --> 00:49:07,400
get you to make your bins more
radial then puts less stress on the innerconductors,

617
00:49:08,639 --> 00:49:13,000
then that's better. If we let
you use the short dimension, then

618
00:49:13,039 --> 00:49:16,159
that would be an awful tight bend, right. But prior to the twenty

619
00:49:16,239 --> 00:49:21,239
twenty three it was kind of debated
which do you use. All of us

620
00:49:22,239 --> 00:49:25,199
in the industry always wanted to use
the major diameter, but it wasn't clear.

621
00:49:25,960 --> 00:49:30,440
And I think that, you know, I remember something, I can't

622
00:49:30,440 --> 00:49:34,960
remember an episode or Ryan or Ryan
Jackson. If y'all haven't checked out Ryan

623
00:49:35,039 --> 00:49:37,760
Jackson's channel, guys, you need
to check out his channel. Just go

624
00:49:37,920 --> 00:49:42,280
to YouTube and search for Ryan Jackson. An amazing resource to the industry,

625
00:49:42,480 --> 00:49:47,360
great guy and a lot of useful
information he provides, does a great job

626
00:49:47,440 --> 00:49:52,039
at it, does a lot of
stuff for the iec IS. We also

627
00:49:52,119 --> 00:49:57,400
share his content over on fast tracks
Tube because he's an amazing educator. But

628
00:49:57,559 --> 00:50:00,000
I think for years he was making
the argument on which which do you use?

629
00:50:01,039 --> 00:50:05,239
You know, and without it being
defined, you know, it's gonna

630
00:50:05,280 --> 00:50:09,840
have to be somebody's interpretation. Now, what usually would happen is an inspector

631
00:50:09,960 --> 00:50:14,800
would say, get with the manufacturer, and as a manufacturer, we would

632
00:50:14,840 --> 00:50:19,880
say, we want you to use
the major. But it wasn't in writing

633
00:50:19,920 --> 00:50:22,639
anywhere. Well now it is.
Now it is, and being that you're

634
00:50:22,679 --> 00:50:29,880
going to use the major, that's
gonna make for a more nice, uniformed

635
00:50:29,960 --> 00:50:34,239
bend rather than a real tight bend. And I've seen people take in him

636
00:50:34,280 --> 00:50:37,320
cable, go over a box,
go down and then turn right away three

637
00:50:37,519 --> 00:50:40,239
sixty no a one eighty, not
three sixty one eighty, and go straight

638
00:50:40,280 --> 00:50:43,440
back up into the box. And
then they want to be neat and they

639
00:50:43,880 --> 00:50:45,719
tighten it all down. And I've
even seen them throw a staple over the

640
00:50:46,400 --> 00:50:50,559
one where it's going down and coming
back up. So two cables under the

641
00:50:50,599 --> 00:50:53,719
staple, and then you've got this
really tight Q tip type bend at the

642
00:50:53,840 --> 00:51:00,039
end, and it obviously exceeds it's
tighter than five times. So that's that's

643
00:51:00,079 --> 00:51:06,039
not good. Long term, that's
not good. So we have those rules

644
00:51:06,079 --> 00:51:07,800
in there, so you make sure
you follow. Now. Of course the

645
00:51:07,880 --> 00:51:10,400
next thing would be securing it supporting. We all know the rules for securing,

646
00:51:10,440 --> 00:51:15,000
for supporting, we're gonna secure them
every well, we're gonna support it

647
00:51:15,119 --> 00:51:19,480
every four and a half feet,
right, that's the golden rule for no

648
00:51:19,559 --> 00:51:23,039
metallic sheet cable, right, and
we're gonna secure it within twelve inches of

649
00:51:23,360 --> 00:51:29,920
every cable entry to an enclosure such
as junction boxes, cabinets and whatnot as

650
00:51:29,960 --> 00:51:32,199
well. Now we also understand that
we do have some other rules. Where

651
00:51:32,239 --> 00:51:37,320
we have a box, for example, that does not have a clamp on

652
00:51:37,440 --> 00:51:42,159
it, or does not have any
type of clamping means, then we're gonna

653
00:51:42,159 --> 00:51:45,880
have to secure it. What We're
gonna have to secure that within eight inches.

654
00:51:47,440 --> 00:51:52,119
Now, that is an example of
where where people say, well where

655
00:51:52,199 --> 00:51:55,440
do I Where do I see that? Where do I go to find that

656
00:51:55,639 --> 00:52:02,519
rule? And that is an exception
under three fourteen dot seventeen B two.

657
00:52:02,760 --> 00:52:07,440
Again, remember I'm in the twenty
twenty twenty three editions, so may not

658
00:52:07,719 --> 00:52:10,760
be the edition you're under. Well, that one's when you have a box,

659
00:52:10,840 --> 00:52:14,679
for example, that's not larger than
two and a quarter by four simple

660
00:52:14,800 --> 00:52:20,239
nail up box, right, simple
carlon, car Carlon, what's the other

661
00:52:20,679 --> 00:52:25,960
cantacs or whatnot? Maybe Fayette Fayette
is that how you say, at Fayette

662
00:52:27,000 --> 00:52:30,800
or Fiat, their brand just simple
nail on boxes that are gonna be two

663
00:52:30,800 --> 00:52:37,320
and a quarter by four. Then
in those then they don't have a connector

664
00:52:37,360 --> 00:52:39,480
built into them, or they don't
have something that secures the cable to the

665
00:52:39,519 --> 00:52:45,159
box. That case, then you'll
need to secure that NM cable within eight

666
00:52:45,239 --> 00:52:52,000
inches, right. So, but
in general, if it has a clamp,

667
00:52:53,159 --> 00:52:55,760
then you're gonna go up to twelve
inches. So remembering the four and

668
00:52:55,760 --> 00:53:02,000
a half feet and the twelve inch
ro is what typically people will remember the

669
00:53:02,079 --> 00:53:08,639
most about non metallic sheet cable,
right makes sense, So that's the part

670
00:53:08,679 --> 00:53:14,000
that you kind of kind of emblazing
you in your mind that type of thing.

671
00:53:14,559 --> 00:53:16,239
And also I always remind people too
that obviously, if you're running through

672
00:53:16,239 --> 00:53:19,880
the framing members, it's considered secured
and supported. You don't have to do

673
00:53:19,960 --> 00:53:22,800
anything extra. But once it comes
out of those board holes or punched holes,

674
00:53:23,119 --> 00:53:27,000
if you're using it in metal studs, which you can use in metal

675
00:53:27,079 --> 00:53:29,760
studs, as long as you put
a gramt in there, it's a full

676
00:53:29,880 --> 00:53:34,480
inclusive grammet okay or bushing that covers
the entire opening so that you don't have

677
00:53:34,559 --> 00:53:38,000
any chance of damaging the sheathing as
you're pulling it as long as once it

678
00:53:38,119 --> 00:53:44,960
starts going horizontal, then you're gonna
have to fall into your securing it every

679
00:53:45,000 --> 00:53:46,920
four and a half feet. If
it's running horizontal, well, if you

680
00:53:47,000 --> 00:53:50,559
come out and go vertical with the
framing member a parallel with it, then

681
00:53:50,559 --> 00:53:54,519
you're gonna have to follow the securing
and supporting rules. If it's running horizontal

682
00:53:54,599 --> 00:53:59,440
through the board holes, then it's
considered secure and supported anyway. And you

683
00:53:59,519 --> 00:54:04,000
probably all know that that probably is
not something I need to tell you,

684
00:54:04,599 --> 00:54:09,079
but it might as well just throw
it out there. Lastly, when we're

685
00:54:09,159 --> 00:54:15,119
talking about the ampacities of the importance
of nomatallogy cable, i'll just cover and

686
00:54:15,159 --> 00:54:17,440
obviously this is not an all inclusive
everything about non metalloghy cable. Trying to

687
00:54:17,480 --> 00:54:21,639
cover as much as I can,
and I think again, I think people

688
00:54:21,719 --> 00:54:24,039
misunderstand the importance of it because you
use it so often. You look at

689
00:54:24,039 --> 00:54:27,599
it and you think, a crap, this is just conductors in a sheathing.

690
00:54:28,599 --> 00:54:32,400
The nuances behind it. One of
the areas I tell people to really

691
00:54:32,480 --> 00:54:40,679
focus on is three thirty four dot
eighty ampacity because it tells you that the

692
00:54:40,800 --> 00:54:45,280
ampacity shall not exceed sixty degree see
or one hundred and forty degrees hair and

693
00:54:45,559 --> 00:54:51,039
Rady conductor. But it then in
the next sentence it says the ninety degree

694
00:54:51,159 --> 00:54:57,679
c rating shall be permitted to be
used for ampacity adjustment and correction calculations,

695
00:54:58,519 --> 00:55:05,800
provided that the final calculated ampacity does
not exceed that of the sixty ye rec

696
00:55:06,079 --> 00:55:09,280
rating conductor. So in our example, we took a twelve at thirty and

697
00:55:09,440 --> 00:55:13,920
after the adjustment of correction it's twenty
one amps, and you're thinking, doesn't

698
00:55:13,960 --> 00:55:17,960
that exceed the sixty No, what
that really means is you can't use it

699
00:55:20,119 --> 00:55:24,119
as twenty one amps. You still
have to follow the values under the sixty

700
00:55:24,239 --> 00:55:29,159
which is the twenty amps, but
you still have a conductor that is more

701
00:55:29,239 --> 00:55:32,840
than adequate to use. If I
had done that adjustment of correction it ended

702
00:55:32,920 --> 00:55:37,639
up being dropping it down to eighteen
amps. Then you have a problem,

703
00:55:38,840 --> 00:55:44,239
especially on all those circuits that require
a minimum of twenty amp circuit like your

704
00:55:44,320 --> 00:55:47,320
small appliance brand circuit, your laundry, your bathroom, those type of things.

705
00:55:47,840 --> 00:55:51,360
You're going to have a cable that
the conductors that are not rated for

706
00:55:51,440 --> 00:55:55,559
twenty that's going to be a problem. So again it's so important to understand

707
00:55:57,719 --> 00:56:02,039
the usage, so important under stand
where we can make adjustments and corrections from

708
00:56:04,000 --> 00:56:06,800
and not just take it for granted
in the field, because many people just

709
00:56:06,920 --> 00:56:10,159
take those things for granted. Okay. It also goes on to say the

710
00:56:10,239 --> 00:56:16,159
ampacity of type N N n MC
cable installed in cable trays again where they're

711
00:56:16,239 --> 00:56:21,760
listed for that marked for that shabby
determined in accordance with three ninety two dot

712
00:56:21,880 --> 00:56:24,840
eighty A. Three ninety two is
the article four cable trays. So you're

713
00:56:24,840 --> 00:56:28,599
gonna get some guidance up there as
well, So keep that in mind.

714
00:56:29,440 --> 00:56:32,559
And then the next two paragraphs are
and I had a hand in it,

715
00:56:32,639 --> 00:56:39,360
and the twenty twenty three I had
my change was in there added to it

716
00:56:39,920 --> 00:56:45,760
dealing with three fourteen dot fourteen A
two and not being able to use the

717
00:56:45,800 --> 00:56:50,559
ten foot ten percent rule. You
can't use it. And that's when you

718
00:56:50,639 --> 00:56:53,440
have maybe an area where the elevated
temperature and then an area where it's not

719
00:56:53,559 --> 00:56:57,920
elevated, and if it's not more
than ten foot of ten percent of the

720
00:56:58,119 --> 00:57:02,159
ten percent of the overall run,
then you get to discount the higher area

721
00:57:02,280 --> 00:57:06,639
that has the higher impacity restriction in
other words, a lot more heat,

722
00:57:06,719 --> 00:57:08,760
so you don't have as much amps
in the conductor because higher heat less amps.

723
00:57:09,079 --> 00:57:13,119
Well, you could discount that and
throw it away if it wasn't more

724
00:57:13,159 --> 00:57:15,920
than ten foot ten percent of the
overall run. Well, that doesn't apply

725
00:57:16,000 --> 00:57:21,440
to non metallic sheet cable. It
can be it can be a lifesaver for

726
00:57:21,559 --> 00:57:24,679
race ways, it can be a
lifesaver for certain applications, but for NM

727
00:57:24,760 --> 00:57:28,719
cable, it's it's not going to
benefit you. So that's what we got

728
00:57:28,800 --> 00:57:34,559
that added in there. And so
so it's important that you do take some

729
00:57:34,719 --> 00:57:37,599
time, especially if you're a residential
person, that you actually do spend some

730
00:57:37,760 --> 00:57:42,440
time in article three thirty four and
look at the ampacities because if you have

731
00:57:42,960 --> 00:57:46,000
more than two M cables, they
contain two or more current carent conductors.

732
00:57:46,039 --> 00:57:50,400
In any fourteen two is going to
have two current carent conductors. So I

733
00:57:50,480 --> 00:57:53,480
am not aware of any non metallic
sheet cable it's not gonna have at least

734
00:57:53,519 --> 00:57:59,079
two current carent conductors in it.
Okay, at least two. I'm just

735
00:57:59,199 --> 00:58:01,119
not a I would know. I
wouldn't know when you would have that application.

736
00:58:01,480 --> 00:58:05,320
The black and white they're always the
white's going to carry the same amount

737
00:58:05,320 --> 00:58:10,000
of current as the black, so
obviously it's current carrying, right. So

738
00:58:10,920 --> 00:58:16,079
where there's more than two so three
n M cables that contain two or more

739
00:58:16,119 --> 00:58:23,559
current conductors are installed without maintaining spacing
between them. Between the cables through the

740
00:58:23,760 --> 00:58:28,400
same opening in wood, like maybe
the top of a panel where you're going

741
00:58:28,440 --> 00:58:32,960
through the top plate or whatnot,
that is to be sealed with thermal insulation,

742
00:58:34,400 --> 00:58:37,920
calk, ceiling foam, you know, filling that gap, and a

743
00:58:38,000 --> 00:58:42,679
lot of times we just would put
the pink insulation in there to seal it

744
00:58:42,960 --> 00:58:45,559
those type of things, And then
later I started using the great stuff pro

745
00:58:45,800 --> 00:58:50,760
the orange because you also have to
maintain the rating of that assembly. Okay,

746
00:58:51,039 --> 00:58:54,280
I think three twenty two and all
that kind of good STUFFE. But

747
00:58:54,400 --> 00:58:59,519
if you're going to do that and
you've got three or more non meatology cables

748
00:58:59,519 --> 00:59:05,639
going through that same board hole,
then you're going to have to apply the

749
00:59:05,719 --> 00:59:14,000
adjustments in three ten fifteen C one. And this is where that dash B

750
00:59:14,239 --> 00:59:21,119
might save your ass. I'm just
saying. Okay, so keeping that in

751
00:59:21,199 --> 00:59:23,199
mind, fourteen twelve tens, you're
pretty much gonna be okay, as long

752
00:59:23,239 --> 00:59:28,440
as you don't exceed nine current caring
conductors. Now, the second one,

753
00:59:29,039 --> 00:59:30,400
okay, that was the that was
through holes, right, that was the

754
00:59:30,679 --> 00:59:35,960
wood framing members. Notice that only
talks about wood framing members. Okay,

755
00:59:37,199 --> 00:59:44,880
not mettle framing members, the wood
framing members. Ironically enough, the next

756
00:59:44,960 --> 00:59:49,599
would be where more than two,
so three or more NIM cables with two

757
00:59:49,639 --> 00:59:52,880
or more current carent conductors. So
pretty much any NM cable are installed in

758
00:59:53,039 --> 01:00:02,599
contact with thermal insulation without maintaining spacing
between the cable. So at any point

759
01:00:04,320 --> 01:00:09,800
they're touching and they're in contact with
thermal insulation, then you're gonna have to

760
01:00:09,840 --> 01:00:13,239
do the exact same thing, and
you're gonna have to potentially, if you

761
01:00:13,360 --> 01:00:16,199
have four or more current Carrent conductors, then you're going to have to do

762
01:00:16,679 --> 01:00:24,280
some type of adjustment. Again,
the beautiful thing that people don't think about

763
01:00:25,400 --> 01:00:30,360
is you can use the ninety because
of the dash B to do your adjustment

764
01:00:30,440 --> 01:00:34,719
and corrected purposes. And you're just
lucky enough to be in a world where

765
01:00:35,280 --> 01:00:37,480
as long as you don't have more
than nine current Carrent conductors and you're dealing

766
01:00:37,519 --> 01:00:39,639
with twelve, fourteen, ten,
let's say then you're not going to have

767
01:00:39,719 --> 01:00:45,360
to do anything, but you at
least should know that that's a benefit.

768
01:00:45,800 --> 01:00:51,199
That's why the dash B is so
important. It's those little nuances that separate

769
01:00:51,320 --> 01:00:54,960
you from everybody else as a contractor, right, that little extra level of

770
01:00:55,039 --> 01:00:59,679
knowledge that you have that other people
don't have. Now, lastly, you

771
01:00:59,760 --> 01:01:01,239
know, I'll just lastly end up
on this. If you ever want to

772
01:01:01,320 --> 01:01:06,199
know how NM cable is constructed,
go to part three of article three thirty

773
01:01:06,199 --> 01:01:09,719
four. You can see the minimum
sizes. It'll become very evident why you

774
01:01:09,760 --> 01:01:14,599
wouldn't use it as service equipment obviously, I mean service entrance cables or anything

775
01:01:14,639 --> 01:01:19,159
like that comes pretty evident. It
tells you that the equipment grounds could be

776
01:01:19,199 --> 01:01:22,360
insulated, cover or bear. Most
manufacturers and non metallity cable do bear.

777
01:01:23,000 --> 01:01:27,880
It does not mean they couldn't insulate
it if they want it, but most

778
01:01:27,880 --> 01:01:31,840
of the time it's bear. And
then also in three thirty four, Dot

779
01:01:31,920 --> 01:01:37,840
one twelve is where you get the
insulation and it reminds you that it's ninety

780
01:01:37,880 --> 01:01:43,840
degrees c and then there's an informational
note that kind of says the dash B

781
01:01:44,960 --> 01:01:49,159
meets this requirement and so that's what
the dash B is all about, and

782
01:01:49,239 --> 01:01:51,639
so I kind of gave you the
history on that, but that's you go

783
01:01:51,760 --> 01:01:54,360
look at three thirty four dot one
twelve and you'll kind of you'll kind of

784
01:01:54,400 --> 01:01:58,800
see that. All right, Okay, guys, I don't know how much

785
01:01:58,840 --> 01:02:00,800
more. I'm the only guy in
the world that can do an hour on

786
01:02:00,920 --> 01:02:02,239
no metallic sheet cable. If I
board the shit out of you, I'm

787
01:02:02,320 --> 01:02:07,480
sorry. This is my world,
You're just living in it. So I'm

788
01:02:07,519 --> 01:02:10,400
gonna do as I want, and
hopefully that I answered your question. Give

789
01:02:10,400 --> 01:02:15,880
you a little more insight about non
metallic sheet cable. If you liked episodes

790
01:02:15,960 --> 01:02:20,239
like this where I go kind of
a little more in depth on the different

791
01:02:20,280 --> 01:02:23,440
wire methods and different things and give
you some of my insight and things like

792
01:02:23,599 --> 01:02:28,679
that, by all means, please
let us know, give us a thumbs

793
01:02:28,719 --> 01:02:32,480
up, share it. Oh oh
wait a minute, I do have one

794
01:02:32,519 --> 01:02:37,079
other thing that I do have to
share about no metallic sheet cable that I

795
01:02:37,239 --> 01:02:42,280
get all the time. I get
this all the time. Can you strip

796
01:02:42,559 --> 01:02:46,239
the individual conductors out of a non
metallic sheet cable and use them in another

797
01:02:46,320 --> 01:02:50,840
race way or some other application like
liquid twite, liquid tight did I say,

798
01:02:50,920 --> 01:02:54,679
liquid twite, liquid tight, Can
I do that? And the answer

799
01:02:54,760 --> 01:03:00,159
to that is absolutely not. Most
of the conductors inside I would venture to

800
01:03:00,199 --> 01:03:05,559
say all manufacturers the conductors that are
inside of no machine nomatology cable are not

801
01:03:05,760 --> 01:03:09,519
marked one because they're not required to
be okay by their standard. That's why

802
01:03:09,599 --> 01:03:14,400
the markings on the sheathing, because
it's supposed to be used as a complete

803
01:03:14,480 --> 01:03:21,119
cable assembly. Now, if there
were markings on the conductor's insulation or whatever

804
01:03:21,239 --> 01:03:25,239
inside of it, then you could
do that, but they're not typically,

805
01:03:25,400 --> 01:03:30,159
so you have to use it as
it is, okay, So you can't

806
01:03:30,199 --> 01:03:34,239
strip it out. The next question
people ask, can I install it in

807
01:03:34,360 --> 01:03:37,960
liquid tide or whatever outside? Absolutely
not. Inside of a raceway is still

808
01:03:38,000 --> 01:03:42,079
a wet location. It can only
be using a dry location, So absolutely

809
01:03:42,199 --> 01:03:49,159
not. You can't do that.
Let's see, there was one more question,

810
01:03:49,800 --> 01:03:54,239
and now I'm drawing a brain fart
that people ask. I'm trying to

811
01:03:54,280 --> 01:03:58,519
remember what it is so I can
share it with you, because I wanted

812
01:03:58,519 --> 01:04:00,719
to end on all these little tidbits. Oh yeah, I remember, I

813
01:04:00,840 --> 01:04:05,519
remember. Now, Okay, So
when you're doing an installation of non metallic

814
01:04:05,599 --> 01:04:13,639
sheet cable and you accidentally tear the
jacket. Remember the jacket brings no insulating

815
01:04:13,719 --> 01:04:18,239
value, it's just a protective sheathing. However, it is damaged, so

816
01:04:18,519 --> 01:04:24,800
you have to repair it with something
that obviously the HJ is gonna feel adequated

817
01:04:24,880 --> 01:04:28,760
with. If you just rip it
and it comes up, but you can

818
01:04:28,840 --> 01:04:34,440
lay it back down, then I
would say electricians tape. You elisted electricians

819
01:04:34,480 --> 01:04:38,239
tape, not the kind you buy
it. As much as I love Harbor

820
01:04:38,320 --> 01:04:42,400
Freight, I don't ever buy their
electrical tape. It's typically usually not you

821
01:04:42,559 --> 01:04:45,400
elisted that. I might be wrong, but I don't ever check, even

822
01:04:45,440 --> 01:04:48,239
though you can buy a big log
of it for hardly nothing. I always

823
01:04:48,280 --> 01:04:51,440
go with the nice tape, whether
it's three M or whatnot. It seems

824
01:04:51,440 --> 01:04:59,519
to be a little thicker, then
you can repair the sheathing. Now,

825
01:04:59,559 --> 01:05:03,679
if it's wholly removed and those conductors
are exposed, then I would recommend that

826
01:05:03,719 --> 01:05:08,920
you have to go with a cable
repair tape. Three M makes a great

827
01:05:09,000 --> 01:05:14,280
cable repair tape, and you can
replace the sheathing. What you can't do

828
01:05:15,920 --> 01:05:19,559
is replace insulation. Now I get
it. You're in the field, you're

829
01:05:19,559 --> 01:05:24,320
working, you've damaged something, you've
stripped off the insulation, you've damaged it

830
01:05:24,440 --> 01:05:27,920
and now copper is showing. My
advice to you is just replaced that piece.

831
01:05:28,719 --> 01:05:31,400
Just replace it. I know the
price of non metallity cable has gone

832
01:05:31,480 --> 01:05:35,400
up in the industry, but is
it really worth it. Just replace it.

833
01:05:36,039 --> 01:05:39,639
Really, it might be a twenty
foot run, ten foot run,

834
01:05:39,679 --> 01:05:42,840
five foot run. Just cut it, just replace it. I'm just giving

835
01:05:42,880 --> 01:05:50,800
you my advice because if something ever
did happen then and they can find it

836
01:05:51,039 --> 01:05:56,559
and follow it back. And trust
me, if you've removed sheathing and insulation

837
01:05:56,719 --> 01:06:00,119
and when it burns up and things
melt away, and if for evaluation,

838
01:06:01,079 --> 01:06:04,119
we will be able to tell whether
or not it was damaged prior. I

839
01:06:04,239 --> 01:06:10,840
know you find that hard to believe, but it will. The discoloration on

840
01:06:10,920 --> 01:06:15,480
the copper is totally different if it
had to if it was insulation under insulation,

841
01:06:15,960 --> 01:06:17,679
or it was bare when it was
exposed. And I'm not going to

842
01:06:17,719 --> 01:06:21,199
give you all the little nuances,
but you don't want to be in the

843
01:06:21,320 --> 01:06:26,199
in that end of an issue.
And if it can happen, it can

844
01:06:26,280 --> 01:06:30,079
happen. Yeah it is. You
know, never say never in this industry.

845
01:06:30,480 --> 01:06:34,079
Okay, so remove it, replace
it. But if it's just the

846
01:06:34,199 --> 01:06:39,559
sheathing. Evaluate it. You know, if you want to contact the manufacturer,

847
01:06:39,559 --> 01:06:43,079
they'll usually tell you that you can
use electrical tape. If you haven't

848
01:06:43,119 --> 01:06:45,480
lost any of the sheathing, it's
just cut or nicked, it's fine.

849
01:06:47,360 --> 01:06:54,519
Electrical tape should be fine. But
if there's actually removal of jacket, then

850
01:06:55,280 --> 01:07:00,480
we recommend a repair tape. It
might not look that pretty, but it's

851
01:07:00,480 --> 01:07:03,800
going to maintain the integrity, so
kind of keep that in mind. So

852
01:07:03,880 --> 01:07:06,519
that's just some little tips I wanted
to give you as an a parting thing

853
01:07:06,559 --> 01:07:10,159
about non metallic sheet cable. I'm
always here to answer your questions. Do

854
01:07:10,239 --> 01:07:12,159
me a favor. If you've got
something you want me to talk about,

855
01:07:12,480 --> 01:07:15,840
just go to Paul Abernathy dot com. Submitted through that portal. Don't email

856
01:07:15,920 --> 01:07:20,239
me. Use the portal and for
you select few that have listened this long

857
01:07:21,440 --> 01:07:27,159
use my twenty five dollars off to
five o FF. Go to fast trastube

858
01:07:27,199 --> 01:07:30,320
dot com. You'll get twenty five
dollars off. You can get annual membership

859
01:07:30,400 --> 01:07:32,800
for one hundred bucks. I promise
you you'll get more than your money's worth

860
01:07:32,840 --> 01:07:36,679
of value out of this new platform
for the videos and things that are going

861
01:07:36,719 --> 01:07:40,400
to be up there, and it's
going to be growing and growing and growing.

862
01:07:40,519 --> 01:07:45,400
This is a multi year project to
create the best repository of videos out

863
01:07:45,440 --> 01:07:50,400
there that have been kind of filtered
down for reliable content, get rid of

864
01:07:50,440 --> 01:07:57,239
all the bs, and it's open
to all types of educators. Everybody's welcome.

865
01:07:57,599 --> 01:08:02,000
So that's it until next time.
Stay safe, God bless and uh,

866
01:08:02,360 --> 01:08:30,600
you know, get out there and
uh and make some money peace as as ask
