1
00:00:14,480 --> 00:00:37,840
Baska. What up? Everybody?
Welcome to another episode of Let's Ask Paul,

2
00:00:37,880 --> 00:00:40,719
the podcast where I Paul abern At
the answer. All of your pressing

3
00:00:40,799 --> 00:00:50,119
questions submitted through are free sponsored by
Wicks Online Portal over at Paul Abernathy dot

4
00:00:50,119 --> 00:00:54,479
com, so check it out.
Just go to Paul Abernathy dot com and

5
00:00:54,719 --> 00:00:57,799
you can submit your questions to me
on the National Electrical Code. In fact,

6
00:00:57,840 --> 00:01:02,960
that's a place that my fast Track
students should be going to submit questions

7
00:01:03,039 --> 00:01:07,840
for the upcoming fast Tracks Live series. It's starting on June twenty eighth,

8
00:01:08,519 --> 00:01:12,280
and that's how they would send questions
in to be answered on the show.

9
00:01:12,480 --> 00:01:18,120
But you can do it too.
Just like today's podcast, I am requested

10
00:01:18,159 --> 00:01:21,640
to answer many things and you can
do all that over at Paul Abernathy dot

11
00:01:21,640 --> 00:01:23,840
com. Pretty cheap, simple,
free. You can't get better than free.

12
00:01:23,920 --> 00:01:27,239
Right, all right, let's get
into today's episode. Today's episode is

13
00:01:27,280 --> 00:01:32,640
a little different because the episode was
sent to me and they sent to me

14
00:01:32,680 --> 00:01:38,120
a question and answer that was from
I guess it's the NIKA Code question of

15
00:01:38,120 --> 00:01:42,079
the day and I've seen these from
time to time and they asked me if

16
00:01:42,079 --> 00:01:45,920
I would comment on it, so
I'm gonna read the question and I'm also

17
00:01:45,959 --> 00:01:49,319
going to read the answer, and
again the answer comes from Nika. This

18
00:01:49,439 --> 00:01:55,760
used to be the old Charles Charlie
Trout. Charlie passed away years ago,

19
00:01:55,840 --> 00:02:00,480
so this is I'm not sure who's
taken this over. But again, it's

20
00:02:00,480 --> 00:02:04,480
been a great series for folks.
It sends you a daily question of the

21
00:02:04,560 --> 00:02:07,799
day. It's kind of like what
we do here, but my questions are

22
00:02:07,840 --> 00:02:14,000
specific to people that submit them into
the system. So but it's a neat

23
00:02:14,120 --> 00:02:16,759
platform. If you've never done it, today just search for Nika Question of

24
00:02:16,800 --> 00:02:21,039
the Day and you can subscribe and
they'll send you a question each day.

25
00:02:21,680 --> 00:02:25,039
So what happened, I guess is
a question kind of was answered or submitted

26
00:02:25,039 --> 00:02:30,280
by an individual, and one of
our listeners saw it and said, you

27
00:02:30,319 --> 00:02:32,599
know, I don't necessarily know if
I if I agree with the answer,

28
00:02:32,639 --> 00:02:37,120
and would I be willing to comment
on it? So I figured, you

29
00:02:37,159 --> 00:02:40,439
know, what the heck, I'd
I'd go on and comment on it and

30
00:02:40,639 --> 00:02:45,439
I'll give you my thoughts on it. So this episode, this question,

31
00:02:45,680 --> 00:02:51,199
I believe if I'm looking, it's
based on Tuesday, May sixteenth, twenty

32
00:02:51,199 --> 00:02:53,840
twenty three. So if you're looking
this up over on the question of the

33
00:02:53,919 --> 00:02:59,680
day over at NIKA. It's from
Tuesday, May sixteenth, twenty twenty three,

34
00:02:59,680 --> 00:03:02,319
and here's the question says, Hello, Charlie, we are seeing more

35
00:03:02,400 --> 00:03:08,840
and more lighted mirrors being installed in
dwelling unit bathrooms. There are a couple

36
00:03:08,840 --> 00:03:14,639
of questions that come up when we
install these units. Number one, would

37
00:03:14,680 --> 00:03:21,599
a mirror light combo mounted on the
wall over the bathroom counter required GFCI protection,

38
00:03:21,879 --> 00:03:25,240
Well, that one's easy. The
answer is no. So the GFCI

39
00:03:25,319 --> 00:03:32,520
protection rule is specific to things like
hydro massage therapy. The receptacles GFCI protection.

40
00:03:34,159 --> 00:03:38,039
The receptacle to serve the countertop within
three feet of the top inside edge

41
00:03:38,039 --> 00:03:43,199
of the bowl. That's GFCI protected. Things like that, Right, any

42
00:03:43,240 --> 00:03:47,439
receptacle that's in a bathroom GFCI protected. Okay, all of that to ten

43
00:03:47,520 --> 00:03:52,400
dot eight, So that's okay.
So if it's built in a mirror that

44
00:03:52,520 --> 00:03:57,080
just has the lighting and all built
into it, then no, there wouldn't

45
00:03:57,120 --> 00:04:00,159
be there's no receptacle there. There
wouldn't be any requirement unless worth the manufacturer's

46
00:04:00,159 --> 00:04:05,240
instructions dictated that. Thank that,
Oh it has to be this, So

47
00:04:05,439 --> 00:04:11,400
generally no to that. So that's
the first part. The second one says,

48
00:04:11,879 --> 00:04:16,480
if the mirror light combo also has
factory installed receptacles built into it,

49
00:04:16,519 --> 00:04:23,120
does it require GFCR protection and is
it required to be supplied by a twenty

50
00:04:23,160 --> 00:04:30,759
amp separate circuit? Requiring required for
bathroom and bathroom receptacles. Thanks in advance

51
00:04:30,800 --> 00:04:34,279
for your input. And the gentleman's
name was Ben Mellows. Okay, so

52
00:04:34,360 --> 00:04:40,600
let me talk about that. So
the the code's pretty clear that you have

53
00:04:40,639 --> 00:04:43,040
to have at least one twenty amp
circuit and this isn't going to be the

54
00:04:43,079 --> 00:04:47,040
one that's going to supply the receptacle
for serving the countertop. Okay, that's

55
00:04:47,079 --> 00:04:51,519
pretty straightforward. We have that rule
and we don't have you know, that's

56
00:04:51,680 --> 00:04:58,079
you know, not debated when it
comes to that circuit. Right, So

57
00:04:58,160 --> 00:05:01,600
now the question is could I have
other receptacles in there? Absolutely, and

58
00:05:01,639 --> 00:05:04,079
do they need to be twenty amp
as well? No, they don't.

59
00:05:04,680 --> 00:05:08,399
You have to have at least one
twenty am but nothing says that we couldn't

60
00:05:08,439 --> 00:05:14,040
have a day receptacle that's fifteen amps
or some other receptacle for a specific need

61
00:05:14,160 --> 00:05:16,959
at fifteen amps as long as we
meet the twenty amp at least one,

62
00:05:17,319 --> 00:05:20,879
and that's the one that's going to
serve the countertop. So that's already met.

63
00:05:20,959 --> 00:05:25,439
That rule is met, so any
additional one doesn't have to be twenty

64
00:05:25,439 --> 00:05:30,639
ams. Now, if you're going
to put that light, that light mirror

65
00:05:30,680 --> 00:05:34,759
combo, that's essentially like a luminaire, so it would be on the branch

66
00:05:34,879 --> 00:05:39,279
circuit that's applying the lighting. Now, if you want to take your own

67
00:05:39,279 --> 00:05:43,800
separate one there, that's fine,
totally up to you for that. Now,

68
00:05:43,800 --> 00:05:48,600
where the second part of this question
gets into it says now it says

69
00:05:48,639 --> 00:05:56,879
if the mirror light combo has a
factory installed receptacle built into it, does

70
00:05:56,879 --> 00:06:00,879
it required GFCR protection and is it
required to be supply by the twenty amp

71
00:06:00,040 --> 00:06:06,839
separate circuit required for bathrooms and bathroom
receptacles like I read earlier. So in

72
00:06:08,000 --> 00:06:13,399
that part of the question, the
receptacle that's in there again does not need

73
00:06:13,439 --> 00:06:16,800
to be twenty AM okay, as
long as you have the receptacles that are

74
00:06:16,800 --> 00:06:20,959
required there to meet the requirements of
two ten dot fifty two D. As

75
00:06:20,959 --> 00:06:27,279
long as they're all in there,
okay, the all receptacles that are in

76
00:06:27,319 --> 00:06:32,759
a bathroom that are one twenty five
through two fifty volt receptacles have to have

77
00:06:33,079 --> 00:06:39,680
GFCI protection period, end of story. So, whether I put a fifteen

78
00:06:39,720 --> 00:06:43,519
AM receptacle in there, a twenty
AM perceptacle in there, the required twenty

79
00:06:43,560 --> 00:06:47,639
amp to serve the countertop within three
feet of the basin, all of those,

80
00:06:48,240 --> 00:06:54,279
if it's in the bathroom, it's
got to be GFCI protected, point

81
00:06:54,319 --> 00:06:59,079
blank. Now. The only exception
to this rule in two ten dot eight

82
00:06:59,160 --> 00:07:02,519
A is where you have one of
the exceptions. And I'm looking at the

83
00:07:02,560 --> 00:07:05,600
twenty twenty three, okay, because
I'm kind of moving forward. In the

84
00:07:05,639 --> 00:07:11,839
twenty twenty three, you have an
exception in here that says exception number four.

85
00:07:12,360 --> 00:07:17,800
It says factory installed receptacles that are
not readily accessible and are mounted internally

86
00:07:17,920 --> 00:07:25,560
to bathroom exhaust fan assemblies shall not
be required, shall not require GFCI protection

87
00:07:25,720 --> 00:07:30,279
unless required by the installation instructions or
the listing. That makes sense, right,

88
00:07:30,480 --> 00:07:35,959
So in this case, if I
have a lighted mirror and it has

89
00:07:36,000 --> 00:07:42,240
built in receptacles, now those receptacles
aren't going to serve the countertop, right

90
00:07:43,000 --> 00:07:46,240
Those are just in addition, they
come with the luminaire, which is a

91
00:07:46,240 --> 00:07:49,920
mirror with the luminaire built into it
that comes with it. The exception that

92
00:07:49,959 --> 00:07:54,959
we read doesn't apply because we're not
talking about a bathroom exhaust fan, right,

93
00:07:55,720 --> 00:07:58,920
So it's built in, but it's
still a receptacle and still could have

94
00:07:59,040 --> 00:08:05,120
stuff plugged into it, right,
Okay. So if that's the case,

95
00:08:05,279 --> 00:08:09,800
and you go look at two ten
dot eight, and those are the ground

96
00:08:09,839 --> 00:08:16,680
fault circuit interrupter protection for personnel rules. It states a dwelling units. It

97
00:08:16,720 --> 00:08:20,800
says all one hundred and twenty five
volt through two fifty volt receptacles installed in

98
00:08:20,879 --> 00:08:26,040
the following locations and supplied by single
phase brand circuits rated on or fifty volts

99
00:08:26,040 --> 00:08:31,120
are less to ground, which it
will be one twenty shall have ground fault

100
00:08:31,159 --> 00:08:37,320
circuit interrupter protection for personnel. And
the number one on the list is bathrooms.

101
00:08:37,879 --> 00:08:41,600
Period. So if the receptacle,
even though it's built into the mirror,

102
00:08:43,279 --> 00:08:46,759
it's still going to be a one
twenty voult through two fifty volt receptacle,

103
00:08:46,320 --> 00:08:50,000
it's still going to be rated one
hundred and fifty volts less to ground.

104
00:08:50,240 --> 00:08:54,720
It's still in the bathroom, it's
still going to be used it would

105
00:08:54,799 --> 00:09:01,799
not want anybody telling me that it
doesn't require GFC oppertuection. Now you say,

106
00:09:01,799 --> 00:09:03,559
well, it's built into the mirror. How would I do that?

107
00:09:03,600 --> 00:09:05,799
Well, y'all know how you would
do that. You put a GFCI breaker

108
00:09:05,799 --> 00:09:09,399
in the panel, you protect everything
downstream. It's not that part's not brain

109
00:09:09,440 --> 00:09:16,039
surgery. Now let me read you
the answer that was given, Okay,

110
00:09:16,639 --> 00:09:20,759
and the reason I didn't elaborate on
things like the shower space and bad because

111
00:09:20,799 --> 00:09:24,759
typically that's not going to come into
play because it's the mirror over the sink.

112
00:09:24,159 --> 00:09:28,000
Okay, But anyway, let me
read you the answer that was given

113
00:09:28,039 --> 00:09:33,080
by the NIKA. And again not
to disparage Nika, I'm just, I'm

114
00:09:33,080 --> 00:09:35,799
just it was I was asked to
follow up on this. The answer that

115
00:09:35,919 --> 00:09:41,639
was given was high ben good question. The ANC would not require GFCI protections

116
00:09:41,960 --> 00:09:46,759
for a light mirror combination unit.
That is correct at that point. However,

117
00:09:46,840 --> 00:09:50,559
if the light mirror unit can't extend
into the tub or shower space as

118
00:09:50,559 --> 00:09:54,399
defined in four ten ten D,
that it must be marked as suitable for

119
00:09:54,480 --> 00:09:58,919
wet and damp locations. And if
the subject of if it's of the sub

120
00:10:00,279 --> 00:10:03,639
two shower spray. It must be
suitable for wet locations. Now, I

121
00:10:03,639 --> 00:10:05,559
didn't even go into that, because
again, what mirror would you put over

122
00:10:05,600 --> 00:10:09,039
your sink that's going to be subject
to that? I mean, be real,

123
00:10:09,840 --> 00:10:11,840
I can promise you the lights that
you put over your vanity aren't rated

124
00:10:11,840 --> 00:10:16,600
for a wet location. Okay,
right, anyway, but that's kind of

125
00:10:16,600 --> 00:10:18,080
went where. I don't know why
it went there, but anyway, I

126
00:10:18,080 --> 00:10:24,200
guess it's covering all bases. It
also says if the light mirror unit also

127
00:10:24,399 --> 00:10:30,679
has a factory install receptacle, it
would could not be used to comply with

128
00:10:30,720 --> 00:10:35,519
the bathroom receptacle requirements found in section
two ten fifty two D. It required

129
00:10:35,559 --> 00:10:39,600
GFCR protection in accordance with two ten
dot AA, it would not be required

130
00:10:39,639 --> 00:10:46,679
to be on a twenty amp circuit
as as section two ten to fifty two

131
00:10:46,720 --> 00:10:52,440
one. Okay, all right,
so I get all that they're talking more

132
00:10:52,480 --> 00:10:58,480
about the spacing in two ten to
fifty two. The I've already covered the

133
00:10:58,480 --> 00:11:03,000
fact that it's as long as you
have the one that's required to be done.

134
00:11:03,320 --> 00:11:05,879
And also to remember, during rough
end, none of that stuff's there

135
00:11:05,039 --> 00:11:09,919
practically, although some of them might
have a rough end kit. You're still

136
00:11:09,919 --> 00:11:13,919
going to have to establish your minimum
of one twenty brand circuit within three feet

137
00:11:13,919 --> 00:11:16,720
of the basin. The twenty amp
one for the basin, you gotta have

138
00:11:16,799 --> 00:11:22,279
that. This is an additional so
these receptacles, it doesn't have to be

139
00:11:22,279 --> 00:11:26,200
twenty It could be a fifteen amp
circuit. But I think what's lacking here

140
00:11:26,679 --> 00:11:31,600
is the fact that it is still
a receptacle. It'll still have something plugged

141
00:11:31,639 --> 00:11:35,960
into it, and it's still in
the bathroom, and it is definitely going

142
00:11:35,000 --> 00:11:39,720
to be at the SINC location.
And the whole intent here is if you

143
00:11:39,840 --> 00:11:46,200
look at two ten dot AA that
it says number one item says bathrooms.

144
00:11:46,480 --> 00:11:50,360
So if it's a receptacle factory installed
or not, if it is in the

145
00:11:50,360 --> 00:11:54,720
bathroom, then it is going to
have to have GFCI protection on it.

146
00:11:54,759 --> 00:11:56,759
So in this case, you're going
to do it back at the panel.

147
00:11:58,279 --> 00:12:01,480
Okay, all right, hopefully that
answered your question on that one. Again,

148
00:12:03,120 --> 00:12:05,440
I don't necessarily one hundred percent agree
with the with the NIKA response to

149
00:12:05,519 --> 00:12:11,039
that one, and probably went off
on some tangents that it didn't need it

150
00:12:11,080 --> 00:12:15,440
to go down when it comes to
the you know about the wet and dry

151
00:12:15,480 --> 00:12:20,639
location application. I hardly think that's
an issue. But the recept But but

152
00:12:20,679 --> 00:12:26,519
the lack of the fact that it's
said nothing about the actual receptacle that is

153
00:12:26,600 --> 00:12:30,159
inside of a bathroom, which somebody
can openly go and plug in a razor

154
00:12:30,279 --> 00:12:33,679
or plug something into it. That's
the whole point of our GFCI protection,

155
00:12:35,399 --> 00:12:41,559
right. So really it wasn't covered
well in the answers, so I guess

156
00:12:41,559 --> 00:12:43,279
that's why the individuals submitted it to
me. So, yes, sir,

157
00:12:43,559 --> 00:12:46,639
it can be on a fifteen or
twenty, doesn't matter when it comes to

158
00:12:46,679 --> 00:12:52,720
the mirror light combo. If it
does have integral receptacles, then yes,

159
00:12:52,600 --> 00:12:56,919
they don't meet the spacing requirement.
Probably you have to look at the rules

160
00:12:56,919 --> 00:13:03,000
in two ten fifty two to see
whether or not it's another type receptacle.

161
00:13:03,600 --> 00:13:05,840
But at the end of the day, you're gonna put your receptacles in and

162
00:13:05,879 --> 00:13:09,679
meet the requirements at two ten dot
eleven, and so you're gonna put your

163
00:13:09,679 --> 00:13:15,440
receptacles in a receptacle within three feet
an outlet, within three feet of the

164
00:13:15,480 --> 00:13:22,720
basin. But these receptacles that are
located integral to the light mirror combo are

165
00:13:22,759 --> 00:13:26,320
most certainly inside of that bathroom,
they most certainly, in my opinion,

166
00:13:26,399 --> 00:13:33,559
and two ten eight a one would
require GFCI protection. And I don't see

167
00:13:33,679 --> 00:13:37,720
anything in any of the exceptions,
even the four of them that were in

168
00:13:37,720 --> 00:13:43,440
the twenty twenty three. I don't
see anything in there that would exempt me

169
00:13:43,519 --> 00:13:48,240
from that protection, because that's what
it's there for, to protect US personnel

170
00:13:48,480 --> 00:13:52,840
persons. Okay, all right,
So that's my take on that Nico question.

171
00:13:52,879 --> 00:13:54,320
If you want to read the question
yourself, and you maybe even reply

172
00:13:54,399 --> 00:14:01,600
to Charlie or whoever's doing them for
Charlie, it is sixteenth, twenty twenty

173
00:14:01,639 --> 00:14:05,440
three when that question came out,
and all you gotta do is go over

174
00:14:05,519 --> 00:14:09,279
to and you search for Nika Question
of the Day and you'll find it.

175
00:14:09,360 --> 00:14:13,159
Go to the archives and look up
that day and you'll see the question again.

176
00:14:13,200 --> 00:14:15,399
It's May sixteenth, twenty twenty three. If you want to do a

177
00:14:15,440 --> 00:14:18,480
follow up to it, to Charlie
and them, ask them that question and

178
00:14:18,799 --> 00:14:22,240
see what they say. But still
a great amazing resource, and they do

179
00:14:22,279 --> 00:14:26,840
a wonderful job over there, Nika
and bringing these questions out every day.

180
00:14:26,919 --> 00:14:30,320
Again, everybody's got an opinion.
That's just how I see it. You

181
00:14:30,320 --> 00:14:33,279
may see it differently, but that's
the beautiful thing about the code. Until

182
00:14:33,320 --> 00:14:35,759
next time, folks, stay safe, God bless. And again, if

183
00:14:35,799 --> 00:14:39,840
you want to get your questions answered
or you want my opinion on something,

184
00:14:41,240 --> 00:14:43,679
just go to Paul Abernathy dot com
and submit it that way. That's the

185
00:14:43,799 --> 00:14:46,600
easiest way to get questions to me. Till next time, folks, Stay

186
00:14:46,600 --> 00:15:16,159
safe, God bless. Both both
asked open ask booth, Open bo